CHANGXUN | Valve Test Equipment

Home / Valve Test Benches / Choosing a bench by test standard

Choosing a valve test bench by test standard — API 598, API 6D, ISO 5208, EN 12266-1, GB/T 13927

Yes, one bench can serve all five standards. The standard on your purchase order decides which tests are run, at what multiple of the rating, on which medium, for how long, and what the record must contain. The bench decides whether you can actually execute that: pressure range at both ends of your valve population, a second low-range gauge for the 1.1× seat readings, an air circuit if the seat test is on gas, a timer, and a log you can hand to a customer. Choose it from the hardest standard-and-size pair you will ever test, not from the biggest word on the order.

Shell 1.5 × ratingSeat 1.1 × ratingWater or airDual-range gauges

Get a quotation  Send the standard and the valve list

Quick answer

Tests these standards call forShell (body) and seat; backseat only where the order names it
Pressure factorsShell 1.5 × rating, seat 1.1 × rating
MediumWater as standard; air or inert gas where the standard and the order permit
What the bench must addRange at both ends, second gauge, air circuit, timer, record
What the bench does not doIt measures. The pass/fail judgement belongs to your QA or the inspector

The standard fixes five things. The bench has to be able to do all five.

Most bench enquiries arrive as "we test to API 598" or "we test to GB/T 13927", and the two sentences sound equivalent. They are, for the pressure arithmetic. They are not equivalent for what has to be on the shop floor. Split the question in two and the specification writes itself.

Fixed by the standard on the orderFixed by the bench you buy
Which tests are performed: shell, seat, and backseat where namedWhether the frame and clamping can hold that valve at that pressure
The test pressure as a multiple of the rating — 1.5× shell, 1.1× seatWhether the gauge can read that pressure to a useful resolution
The medium allowed: water, air, inert gas, kerosene in some house specsWhether a gas circuit exists at the pressure the seat test needs
The hold time, which is banded by size in the standard's tableWhether the timer is set from that table instead of a default
The acceptance criterion: a leakage rate, a class letter, or "no visible leakage"Whether the bench can measure and log a rate at all, and in what format

Nothing in the left column is negotiable at the bench. Everything in the right column is what the quotation has to settle, and it is settled by the valve population rather than by the standard's name.

The five standards, side by side

The shell and seat factors below are the same across the five: 1.5 times the rating for the shell test, 1.1 times for the seat test. What differs is the scope, the wording of the acceptance criterion, and therefore what the bench has to record. The rate tables themselves — the ISO 5208 classes and how the API 598 allowables map onto them — are set out on the leakage rate classes page, so this page does not repeat them.

StandardWhat it is written forWhat it asks of the testWhat that forces on the bench
API 598Steel gate, globe, check, plug, ball and butterfly valves, general serviceShell at 1.5× and seat at 1.1× of the rating, backseat where specified; hold time banded by size; allowable leakage given per size and seat type, in drops per minute for liquid and bubbles per minute for gasA rate that can be counted or measured, not just a pressure held: clear water, a sight path to the seat, a timer, and a log that carries size, class and medium
API 6DPipeline valves, where the valve is part of a line and the seat has to hold in both directionsShell at 1.5× and seat at 1.1× of the cold working pressure; seat acceptance for metal-seated valves is written into the order rather than into a single fixed tableThe order's agreed rate has to be measurable and repeatable, so each seat direction is tested and recorded separately — the fixture has to allow that without re-clamping the body
ISO 5208Industrial valves, international; the base that several national standards followShell at 1.5× and seat at 1.1×, with leakage expressed as rate classes rather than as a single number; class A is no visible leakageA class A test is a visual test: clean water, light on the seat, and a low-range gauge so the 1.1× pressure is set precisely enough to defend the result
EN 12266-1Industrial valves, European practice, often quoted alongside a PED or a project specificationThe same two factors, with its own lettered rate series and its own hold-time tableDo not assume a letter means the same number as an ISO 5208 class. The class letter is quoted with the standard it comes from, and the recipe is built per standard
GB/T 13927Industrial valve pressure testing in Chinese practice; the standard most often written on orders placed through Chinese end users and EPC contractorsFollows the ISO 5208 structure: shell 1.5×, seat 1.1×, lettered leakage rates, hold time by sizeNothing extra mechanically — but the record sheet is often required in Chinese, so the export format has to be settled at the quotation stage

If your order names API 6D specifically, the API 6D valve testing page walks the whole pipeline-valve sequence — both seat directions, the low-pressure air leg, the DBB cavity checks — and shows which benches carry each leg.

Editions and project specifications override all of this. When the order names a standard edition or a customer specification, the recipe is built from that document, and this page is only the shopping list for the machine that will run it.

The four bench features these standards actually force

1. Range at both ends, not just at the top

The seat test is the low-pressure half of the job and it is the half that gets forgotten. A PN16 valve seats at 1.76 MPa; a PN250 valve seats at 27.5 MPa; a PN400 valve shells at 60 MPa. A bench chosen only for its headline pressure cannot cover the small valves in the same shop. The test pressure chart lists both columns for PN10 to PN400, and the size-first table settles the frame; read them together before the model is picked.

2. A second, low-range gauge — this is the one that changes results

Put a 1.76 MPa seat reading on a gauge whose full scale is 40 MPa and the pointer sits at 4.4 per cent of the dial. A gauge of the usual 1.6 per cent full-scale accuracy is then uncertain by about ±0.64 MPa — more than a third of the reading, which is wider than the difference between one class and the next. On a 4 MPa gauge the same accuracy gives about ±0.064 MPa, roughly 3.6 per cent of the reading. That is why the benches are quoted with two ranges and a changeover, and why a bench sold with one 40 MPa gauge is cheap in the wrong place.

3. A gas circuit, if the seat test is on air

Where the standard and the order allow the seat test on gas, the air pressure has to reach 1.1× the rating of the smallest class you test on gas. On the current range the air circuits are 0.8 MPa on the YSYJ-300, 4 MPa on the SYJ-600SQ and 20 MPa on the WBD-400; the SYJ-150 and the vertical single-station frames are water only. A 0.8 MPa circuit covers the seat test of PN6 valves and stops there, because 1.1× of PN10 is 1.1 MPa. If air testing is on the order for PN16 and above, the bench has to be chosen for the air circuit first and the frame second. The medium choice itself — why water is the default and what a gas leg changes on detection, gauges and safety — is set out on the pneumatic vs hydrostatic page.

4. A record, in the shape the customer will accept

All five standards produce a result that somebody may have to re-check months later, so the bench has to log the pressure at hold, the hold time, the medium, the size and class, and the operator. That is a control-system question, not a mechanical one, and the eight steps the record has to follow are on the hydrostatic test procedure page. The data export page sets out what can come off the machine and in what format, and what it deliberately does not do — it does not decide pass or fail, and it does not issue a certificate.

Which bench for which standard-and-size pair

The rows below are the combinations that arrive most often. Each one is a pressure and clamping statement only; the fixture set is planned afterwards against the actual valve list.

Order saysTypical size bandWhat it needsModel that fits
API 598, water only, small valve repair shopDN15–DN150Up to 40 MPa water, 30 t clampSYJ-150
API 598 or GB/T 13927, mixed classes on one benchDN50–DN3001.6–40 MPa water, 80 t clamp, dual gaugeZSYJ-300A
API 598 with gas seat tests, or ISO 5208 class A on mixed sizesDN50–DN60040 MPa water plus a 4 MPa air circuit, 90 tSYJ-600SQ
API 6D, pipeline valves, low classes and large boresDN350–DN600Up to 16 MPa, 150 t, valve laid flatWBD-600
PN400 / Class 2500 shell testany60 MPa shell — above a standard 40 MPa water benchNot a catalogue model: pump, frame and plate thickness change

A PN250 valve shells at 37.5 MPa and seats at 27.5 MPa, which a 40 MPa water bench reaches; the step above it does not fit inside the standard envelope, and no amount of control-system work moves that ceiling. Where the population straddles both ends, the honest answer is a two-station frame rather than one over-specified machine — the valve-type page deals with how the fixture follows the valve, and the bench overview carries the full model table.

When two standards are on the same order

It happens on export jobs: the valve is built to one standard and witnessed to another, or the end user writes GB/T 13927 while the contractor writes API 598. The rule is simple and it is not a compromise — the harder of the two governs the machine, and both are named on the record. The pressure arithmetic rarely differs; what differs is the hold time, the medium and the shape of the acceptance criterion. All three live in the recipe, so the same bench runs both, and the operator selects the standard rather than remembering it.

Boundaries worth writing down

The bench does not declare a valve compliant. It produces a pressure record and a leakage observation. Whether that satisfies API 598, ISO 5208 or GB/T 13927 is a judgement made by your quality function or by the inspector named on the order.

The standard edition on the order governs. Where an edition, a project specification or a customer procedure is named, the recipe is built from that document and not from a default.

The envelope is mechanical. A 40 MPa water bench does not become a 60 MPa bench through software, a bigger pump or a different gauge.

No third-party witness is implied. If the order requires an inspector to witness the test, that is arranged separately and in advance.

What to put in the enquiry

Six lines are enough for us to size a bench against a standard. Without them the quotation is a guess about somebody else's valve population:

Send that list and the answer comes back as a model, a fixture set and a test recipe per standard — not as a brochure page.

What that reply turns into, line by line, is worth reading before you compare suppliers. The price and lead time page opens up the quotation into its twelve lines, shows which configuration choices move the number, and explains why the delivery date starts at the configuration freeze.

Frequently asked questions

Can one bench test to API 598 and ISO 5208 at the same time?

Yes. The two share the shell 1.5× and seat 1.1× factors, so the machine is the same. What changes is the acceptance wording — API 598 gives an allowable leakage per size and seat type, ISO 5208 gives a rate class — and the hold time table. Both are stored as separate recipes, and the record names the one that was run.

Do I need an air circuit to test to API 598?

Only if the order specifies a gas seat test. API 598 allows the seat test on water, and many workshops run everything on water because it is simpler and the leakage is easier to see. Where the order does call for air, the circuit has to reach 1.1× the rating of the highest class tested on gas: 4 MPa on the SYJ-600SQ, 20 MPa on the WBD-400, and 0.8 MPa on the YSYJ-300, which stops at PN6.

Is a 40 MPa bench enough for Class 2500 or PN400?

Roughly, no. A PN400 valve shells at 60 MPa and seats at 44 MPa, so the shell test is above the standard 40 MPa water envelope. PN250 is the class where a 40 MPa bench still arrives — 37.5 MPa shell, 27.5 MPa seat — and the step above it needs a machine specified for it rather than a standard model with the pressure raised on paper.

Which standard applies to a valve built in China for export?

Whichever one the purchase order names. The origin of the valve does not decide it: an order to a European buyer may cite EN 12266-1, a pipeline project may cite API 6D, and a domestic end user will usually cite GB/T 13927. The bench is specified from the order's standard, and the record is written in the format that order accepts.

Does a class letter mean the same thing in ISO 5208 and EN 12266-1?

Do not assume it does. The two standards define their own lettered rate series, and a letter without its standard is an incomplete specification. When the order cites a class, quote the standard with it; the recipe is then built from that standard's table, and the record shows both.

Can the bench produce the test certificate itself?

No. It produces the measurement record: pressure, hold time, medium, size, class, operator, and the leakage observation. The certificate is issued by the party entitled to issue it — the manufacturer's quality department or the inspector on the order. We supply the record and, where the machine is equipped for it, the export in the format the customer's system accepts.

Tell us the standard and the valve list.

Send the standard, the DN range and the pressure classes. We come back with the model, the fixture set and the test recipe per standard — and say plainly where the envelope stops.