Valve Hydrostatic Test Pressure Chart — shell 1.5 × PN, seat 1.1 × PN, PN10 to PN400
Two multiplications set the test pressure of almost every valve: the shell (strength) test at 1.5 × the 38 °C rating, and the seat leakage test at 1.1 × the same rating. This page does the arithmetic in MPa from PN10 to PN400, adds the API 598 hold times by size, and then maps each class to the bench that actually reaches it — because the machine is sized by the highest class in your workshop, not by the average one, and the clamp follows the sealed area rather than the dial.
Quick answer
| Shell test | 1.5 × rating at 38 °C |
|---|---|
| Seat test | 1.1 × rating at 38 °C |
| PN16 | 2.4 MPa shell / 1.76 MPa seat |
| PN40 | 6.0 MPa shell / 4.4 MPa seat |
| PN100 | 15 MPa shell / 11 MPa seat |
| PN160 | 24 MPa shell / 17.6 MPa seat |
| PN250 | 37.5 MPa shell / 27.5 MPa seat |
| PN400 | 60 MPa shell / 44 MPa seat |
Test pressure by class, PN10 to PN400
The table applies the two factors to the nominal pressure classes met in a valve workshop. It is arithmetic, not a substitute for the specification: if the enquiry names a standard edition or a project specification, that document governs. Read the MPa column carefully — a PN16 valve is tested at 2.4 MPa, not at 24 — and note that the bench column is about pressure only. Size and clamping are dealt with further down the page.
| Class | Rating at 38 °C MPa | Shell test 1.5 × MPa | Seat test 1.1 × MPa | Bench that reaches it |
|---|---|---|---|---|
| PN10 | 1.0 | 1.5 | 1.1 | Any bench in the range — DFS2-600 at DN50–600 |
| PN16 | 1.6 | 2.4 | 1.76 | Any bench in the range — the DN sets the model, not the pressure |
| PN25 | 2.5 | 3.75 | 2.75 | Any bench in the range |
| PN40 | 4.0 | 6.0 | 4.4 | 7 MPa water — DFS2-600, SYJ-600M |
| PN64 | 6.4 | 9.6 | 7.04 | 10 MPa — SYJ-600M to DN600 |
| PN100 | 10 | 15 | 11 | 16 MPa — WBD-600, DN50–600 at 150 t |
| PN160 | 16 | 24 | 17.6 | 40 MPa water — ZSYJ-300A, SYJ-150 |
| PN250 | 25 | 37.5 | 27.5 | 40 MPa water — SYJ-600SQ for the larger sizes |
| PN400 | 40 | 60 | 44 | Above a standard 40 MPa water bench — pump, frame and plate thickness change |
Rating at 38 °C per the PN series; the 1.5 and 1.1 factors are those of API 598 and GB/T 13927 for the shell and seat tests. Values rounded to two decimals. For Class 150 / 300 / 600 / 900 / 1500 / 2500 valves, use the 38 °C rating from the applicable ASME table in place of the PN rating — the same two factors apply.
Why the class and the size have to be read together
A bench is bought to cover the hardest valve that will ever be put on it, and that valve is often neither the largest nor the highest-rated one — it is the one carrying the most sealed area at the highest pressure on the same day.
Two numbers make the point. A DN500 valve at PN16 is tested at 2.4 MPa, which sounds modest, but the sealing plate presents about 0.2 m² to the water: 2.4 MPa over that area is roughly 47 tonnes of force pushing the valve off the plate, so the clamp has to be rated well above it. A DN50 valve at PN250 is tested at 37.5 MPa — fifteen times the pressure — but the plate is a hundred times smaller in area, and the separating force is about 7 tonnes.
The small high-pressure valve is the easy one mechanically, and it is the one buyers worry about. The large low-pressure valve is where benches get heavy, where plates get expensive, and where a clamp quoted on tonnage alone turns out to be marginal. A quotation built from the pressure class alone will be wrong for the size actually tested.
Hold time: the second variable
Reaching the pressure is half the test. The other half is how long the bench must hold it, and that scales with size rather than class. Under API 598 the minimum shell test duration is:
| Size | Minimum shell test duration |
|---|---|
| Up to NPS 2 (DN50) | 15 s |
| NPS 2½ – 6 (DN65 – DN150) | 60 s |
| NPS 8 – 12 (DN200 – DN300) | 120 s |
| NPS 14 and larger (DN350 +) | 180 s |
Values as published in API 598 for the shell test. Project specifications frequently require longer holds, and some buyers add a visual inspection interval on top. Always confirm against the edition named in the enquiry.
Three minutes at DN600 is short on paper and long in a workshop: on a manual bench it is three minutes of an operator watching a gauge, per valve, per shift. On a PLC bench the same hold is timed, logged and printed without attendance — which is usually the real argument for automatic control, not the pressure rating.
Four worked examples
| What you test | Shell test | What decides the model |
|---|---|---|
| DN25 – DN100, PN16 butterfly valves | 2.4 MPa | The DN range, not the pressure. Any bench in the range reaches 2.4 MPa; SYJ-150 covers DN15–DN150 with 30 t clamping |
| DN200 gate valves, PN100 | 15 MPa | Pressure and size together: WBD-600 (0–16 MPa, 150 t) or ZSYJ-300A (1.6–40 MPa, 80 t) with the DN200 plate |
| DN500 butterfly valves, PN16 | 2.4 MPa | Clamping and plate size: WBD-600 (150 t) or SYJ-600SQ (90 t, water and air) |
| DN50 valves, PN250 | 37.5 MPa | Pressure on a small plate: SYJ-150 or ZSYJ-300A |
| DN800 valves, PN10 | 1.5 MPa | Above the standard DN600 ceiling — send the requirement, larger frames are built to order |
Read the third and fourth rows together. The DN500 valve at PN16 and the DN50 valve at PN250 need almost the same machine from opposite ends of the pressure range — one because of area, the other because of pressure. That is the whole argument for sending both numbers.
What the bench must do besides reach the pressure
- Clamp the plate area, not the bore. Clamping force follows the sealed area at the test pressure: a DN500 valve at 2.4 MPa needs far more clamping than a DN50 valve at 37.5 MPa. Ask for the separating force at the worst case, then compare it with the tonnage quoted.
- Hold the pressure to the specified time. Automatic hold with a timer, not a manual valve and a clock on the wall.
- Read the low pressures properly. A 1.1 MPa seat test on the bottom of a 40 MPa dial is unreadable. Two gauges, one per range, is the difference between a measurement and a guess.
- Record what happened. PLC benches log pressure, hold time, operator and result per valve serial number; some buyers' QA systems accept nothing less.
- Separate the water and air circuits. On a dual-medium bench such as the SYJ-600SQ, the air circuit to 4 MPa is used where a water residue is unacceptable or the specification calls for a gas test.
- Guard the operator. Pneumatic testing stores energy; interlocks, guarding and a pressure-relief path belong in the specification, not in the accessories list.
Frequently asked questions
Is the shell test always 1.5 times PN?
Normally yes: 1.5 times the pressure rating at 38 °C, which is the basis of API 598 and GB/T 13927. Some project specifications use 1.5 times the design pressure at the operating temperature instead, and for some materials that is higher than 1.5 × PN. The standard or specification named by the inspector governs — the chart above is the arithmetic, not a substitute for the specification.
Can a 40 MPa valve test bench test a PN400 valve?
Not the shell test. PN400 needs 60 MPa for the shell test and 44 MPa for the seat test, both above the 40 MPa water range of a standard bench. A PN400 programme changes the pump, the frame and the sealing plate thickness, so the configuration has to be confirmed in writing rather than taken from a catalogue table.
Why does a DN500 PN16 valve need a bigger bench than a DN50 PN250 valve?
Because the clamp follows the sealed area, not the dial. A DN500 plate presents about 0.2 m² to the water; at the PN16 shell pressure of 2.4 MPa that is roughly 47 tonnes of separating force, so the clamp has to be rated well above it. A DN50 plate at the PN250 shell pressure of 37.5 MPa separates with about 7 tonnes. The large valve at the low class is the harder job, which is why large-bore benches are quoted by tonnage as much as by pressure.
How long must the test pressure be held?
Under API 598 the minimum shell test duration is 15 s up to NPS 2, 60 s from NPS 2½ to 6, 120 s from NPS 8 to 12 and 180 s from NPS 14 upwards. A PLC bench holds the set time, judges pass or fail and prints the record; a manual bench relies on the operator and a stopwatch.
Which bench covers DN50 to DN300 at PN160?
ZSYJ-300A: DN50 to DN300, water 1.6 to 40 MPa, 80-ton clamping. The PN160 shell test is 24 MPa and the seat test 17.6 MPa, both inside the 40 MPa water ceiling with margin for a longer hold written into the specification.
Which bench covers DN600 at PN100?
WBD-600: horizontal, DN50 to DN600, water 0 to 16 MPa, 150-ton clamping cylinder. PN100 needs 15 MPa for the shell test and 11 MPa for the seat test, which the 16 MPa ceiling covers at every size in the range. For PN160 at DN600 the pressure is outside that ceiling and the model changes.
Benches that cover these classes
For the step-by-step operation of a bench — clamping, venting, holding, judging and recording — read the hydrostatic test procedure. For how much leakage is allowed while the pressure is held, read the leakage rate classes. For the wider selection logic — clamping force, water versus air, vertical versus horizontal, station count — read the valve pressure test bench buyer guide.