CHANGXUN Valve Test Equipment
Home › Buyer guides › Valve pressure test bench

How to Specify a Valve Pressure Test Bench

Most valve test benches are bought on one number — clamping tonnage — and that is the number most often misread. This guide covers the five decisions that actually determine whether a bench tests your valve range quickly and safely: clamping force, test medium, layout, station count and control.

DN15 – DN600Up to 40 MPa water30 – 150 t clampVertical / horizontal

1. Clamping force, and why tonnage alone is not a specification

The clamp only has to do one thing: keep the sealing plates closed against the force that test pressure pushes them apart. That force grows with the area the pressure acts on — which is the sealing plate area, not the valve bore. A DN300 valve with a 400 mm sealing plate at 4 MPa produces roughly 28 tonnes of separating force; the same valve with a plate sized for a larger face produces more.

So ask two questions, not one: what clamping tonnage, and what sealing plate diameters does it cover? Our 80-tonne class (ZSYJ-300A, DN50 – DN300) and 90-tonne class (SYJ-600SQ, DN50 – DN600) are sized on that basis. A bench quoted at 100 tonnes with plates smaller than your valves tells you nothing.

2. Water, air, or both

Water is the default for shell and seat tests because a failed seal releases almost no stored energy. Air testing is quicker and leaves no drying, but it has to be a bench designed and rated for gas service, with a guarded working area and a pressure regulator that cannot be overrun.

If you need both, the two circuits must be separate. The SYJ-600SQ carries water to 40 MPa and air to 4 MPa on one frame with independent circuits — the air side is not a low-pressure tap off the water pump.

3. Vertical or horizontal layout

Vertical benches clamp from above onto a fixed base plate. They are compact, the operator stands close to the seals, and they suit valves up to about DN300. Above that, the problem is no longer pressure, it is handling: a DN500 cast steel gate valve is heavy and awkward to stand on end.

Horizontal benches — our WBD-600 covers DN50 – DN600 — load from the side, with a Ø250 mm top cylinder at 150 tonnes and a three-jaw side arrangement (3 × Ø140 mm, 100 tonnes each) that holds the body while the ends are sealed. Cycle time per valve goes down mainly because nobody is lifting the valve onto a vertical frame.

4. One station or two

A single-station bench is limited by operator time, not by pump capacity: loading, clamping, filling, holding, draining and unloading a DN200 valve is a few minutes of work. If your output is more than a few hundred valves a month, a double-station bench (DFS2-600) lets one valve be tested while the other is being changed, and the pump is shared.

For gate valves in continuous production, the next step is a dedicated automatic line such as the ZZC2-200, where clamping, filling, holding and draining are sequenced by PLC and the operator only loads and unloads. That is worth considering only when the product mix is stable enough to justify the fixed tooling.

5. Control and records

Manual control with a dial gauge and a hand valve is still the most common configuration worldwide, and it is perfectly adequate if nobody asks you for test records. As soon as a customer, an inspector or a standard asks for a pressure curve per valve, you need PLC control with pressure logging and an export file.

Decide this before you buy, not after: retrofitting logging onto a manual bench means replacing the control valve, adding a transducer and rewriting the panel. It is cheaper to specify it at order time.

Which Changxun model fits your valve range

Your valve rangeTypical model
DN15 – DN150, up to 40 MPaSYJ-150 — vertical, 30-tonne clamp, water to 40 MPa
DN50 – DN300, up to 40 MPaZSYJ-300A — vertical, 80-tonne clamp
DN50 – DN400, up to 40 MPaYSYJ-300 — vertical, 80-tonne clamp
DN50 – DN600, verticalSYJ-600M / SYJ-600SQ — 90-tonne top cylinder Ø200, water 40 MPa / air 4 MPa on the SQ
DN50 – DN600, horizontal, large bodiesWBD-600 — Ø250 mm top cylinder 150 t, 3 × Ø140 mm side jaws 100 t each, water 0 – 16 MPa
Small valves in high volume, max DN100SYJ4-150 — four-station, 4 × 30 t, 0 – 25 MPa
Double-station production testingDFS2-600 — two stations sharing one hydraulic power pack
Automatic gate valve lineZZC2-200 — PLC-sequenced, two stations

Ratings above are the published specifications of each model. If your valve range crosses two of these bands, tell us the full range and we will quote the single bench that covers it rather than two.

Send this with your enquiry

Frequently asked questions

How much clamping force do I need for a valve test bench?

Clamping force must exceed the separating force the test pressure creates on the largest sealing area you will test. For a DN300 valve at 4 MPa the separating force is roughly 28 tonnes, so an 80-tonne clamp covers it with margin. Do not size the clamp only on nominal bore: the sealing plate diameter, not the bore, defines the area.

Should the bench test with water or with air?

Water is the default for shell and seat tests because it stores little energy if a seal fails. Air testing is faster and leaves no drying work, but it requires a bench built and rated for gas service, with a guarded test area. A bench that offers both needs separate pressure circuits: for example the SYJ-600SQ runs water to 40 MPa and air to 4 MPa.

Vertical or horizontal test bench?

Vertical benches with a top clamping cylinder suit valves up to roughly DN300 and keep the operator close to the sealing plates. Above DN300 a horizontal bench is easier to load: the valve rolls or is craned onto a cradle and the clamping cylinders travel sideways, which avoids lifting a heavy body onto a vertical frame.

What hold time should the bench support?

Specify the hold time your standard requires and confirm the bench holds pressure without pump cycling during that period. A bench that leaks down and re-pumps during the hold gives unstable readings. Ask for a demonstration at your maximum test pressure held for your full hold time, not a short burst.

What should a quotation include?

Sealing plate sets for your diameter range, spare sealing elements, clamping tonnage and cylinder bore, test circuit pressure, control type (manual, PLC, logging), electrical specification, English manual and wiring diagram, and commissioning terms. A tonnage figure without the circuit pressure behind it is not a specification.

Related models

SYJ-150

  • DN15 – DN150
  • 0 – 40 MPa water
  • 30-tonne clamp
View SYJ-150 →

SYJ-600SQ

  • DN50 – DN600
  • Water 40 MPa / Air 4 MPa
  • 90-tonne top cylinder
View SYJ-600SQ →

Whole range

  • Vertical and horizontal
  • Single, double, four station
  • Manual or PLC control
Compare test benches →
Tell us your valve range and we will size the bench

Send valve types, DN range, pressure class and required hold time. We reply within 12 working hours with a model recommendation, datasheet and price.

Request a quotation