Home / Buyer Guides
Buyer guides: choosing a valve pressure test bench
Straight answers on clamping force, pressure range, layout and cycle time — written from the machines we build, not from a catalogue.
How to use these guides
There are two paths through this section. If you already know your valve range and test pressures, the selection-by-DN guide and the model pages take you straight to a machine. If the specification is still open — clamping force, water versus air testing, layout, station count — start with the full buyer guide below, then use the technical references when you need the details behind an answer.
Start with these two guides
How to specify a valve pressure test bench
How clamping force follows sealing plate area rather than bore, when water or air testing applies, vertical versus horizontal layout, one or two stations, and a model finder covering DN15 to DN600.
Read the guide →Choosing a bench by valve bore (DN15–DN600)
Test pressure and clamping force are only half of the specification. Bore size drives the physical envelope: daylight between the clamping plates, sealing plate diameter, tooling for wafer and double-flange bodies, and the floor space the machine actually needs. This guide walks DN15 to DN600 in six bands and shows where each standard model fits — and when a custom bench is the honest answer.
Choose by bore size →How the buying decision actually breaks down
Most test bench inquiries stall because the specification is incomplete. The five questions below are the ones our engineers ask before quoting anything; each links to the reference that explains it in depth.
- Define the test pressures first. Shell and seat test pressures follow the pressure class of the valve, not the machine: hydrostatic shell testing is commonly specified at 1.5 times rated pressure and seat testing at 1.1 times, following API 598 and ISO 5208 practice. The hydrostatic test pressure chart maps PN10 through PN400 to those values, so you can check any machine’s range against your own valve classes.
- Translate pressure into clamping force. The force the bench must hold is the test pressure acting over the sealing plate area — it grows with the square of the bore, which is why a DN500 body is a different machine class from a DN50 one. The clamping methods guide covers the force path and the rigging options.
- Choose the layout for your valve type. Vertical benches suit globe, check and safety valves that test with the flow axis vertical; horizontal benches handle long gate valves and large bores. The horizontal vs vertical comparison lists the trade-offs in handling, tooling and floor space.
- Decide water, air, or both. Shell tests are normally hydrostatic; low-pressure air seat tests are what actually find many seat leaks. If your standard calls for both, look at a dual-media machine such as the SYJ-600SQ water and air test bench instead of planning a second purchase later.
- Size the stations to your throughput. A single station is fine for workshop and sample testing. If valves queue for the bench every shift, a dual-station bench roughly doubles daily throughput without a second operator, because one valve is being rigged while the other is under pressure.
Technical references behind every quotation
These are the references our own engineers use when they answer an inquiry. They are written so you can check our answers, not just read them.
- Valve hydrostatic test procedure — the step-by-step shell and seat test sequence, from mounting to pressure hold and drain-down.
- Hydrostatic test pressure chart — PN10–PN400 translated into shell (1.5×) and seat (1.1×) test pressures.
- Valve leakage rate classes — what API 598 and ISO 5208 actually accept as “zero leak”, in drops, bubbles and volume per time.
- How to test a gate valve — a worked example from mounting to pass/fail, with the failure modes that show up on a real bench.
- Horizontal vs vertical test bench — which layout fits your valve family, and what each costs you in handling.
- Valve test bench clamping methods — how the sealing force is generated, measured and kept safe at high pressure.
- Test record and pressure curve — the documentation a third-party inspector expects to see with a tested valve.
- FAT checklist — what to agree on before the factory acceptance test, so the machine signs off the first time.
- Selection by DN — the six bore bands and the model that covers each.
- Testing by valve type — how gate, ball, butterfly, check and globe valves differ on the bench, and the fixtures each one needs.
Questions that come up again and again — delivery time, testing media, spares, warranty terms — are answered on the FAQ page.
What to send us for an accurate quotation
A one-line inquiry (“price for a test bench”) can only get a catalogue answer. The inquiries we turn into orders contain six things:
- Valve types you test — gate, globe, check, ball, butterfly, safety — and the governing standard (API, GB/JB, EN)
- Your DN range: the smallest and largest bore you actually put on the bench
- Pressure classes or rated pressures, so the shell and seat test pressures can be derived from the chart above
- Test media: water only, or water and air
- Expected test volume per shift, so station count and cycle time are matched to reality
- Available floor space and power supply at your plant
Send those six points and we reply with a specific model, the fixtures it needs, and a real delivery date — not a brochure. Start from the inquiry form or write to us directly.
Not sure which bench fits your valve range? Send the valve types, DN range and test pressure — we answer with a specific model and a real delivery date.
Ask for a model recommendation