The factory acceptance test — the last look before the crate is closed

Once a test bench is packed, every problem it carries becomes your problem at the dock, in customs, and on your workshop floor while your production waits. A factory acceptance test (FAT) is not a ceremony; it is a structured few hours in which a defined list of things is checked and the results are written down. This page is that list — six groups of checks for a hydrostatic valve test bench, a suggested test agenda for the day, and the paperwork to settle before the machine ships.

FATAcceptancePressure calibrationRecords

Get a quotation  Request a FAT agenda

Quick answer

Who runs the testYou or your inspector, with the supplier's test engineer
What valve is testedA representative valve from your production, at its real shell and seat pressures
What is recordedHold time against the timer, the time–pressure curve, the pass/alarm result
What ships with the machineTooling for the full DN range, spare seals, English manual, wiring diagram
If you cannot attendSame agenda run live over video call

Why acceptance before shipment, not after arrival

A test bench that fails at your factory does not just cost a repair. It costs the weeks between the claim and the resolution: the part that has to be sent, the engineer who has to travel or guide by video, and the test records your own customers are waiting for in the meantime. Everything that can be discovered in the supplier's workshop costs hours there; the same thing discovered after arrival costs weeks. That asymmetry is the whole argument for a structured FAT.

It also sets the baseline for later. The records exported from the machine during the FAT run are the reference your team can compare against a year later when a reading looks wrong — pressure calibration drifts, and a baseline is how you tell machine drift from valve rejects. For what the gauge can and cannot tell apart, see the notes on clamping and sealing fixtures.

Group 1 — identity and documentation

Group 2 — the pressure path

Group 3 — the hold, the timer and the acceptance factor

A hydrostatic test is a closed volume, a set pressure, and a hold time. Two settings decide whether two benches judge the same valve the same way, and both belong in the FAT:

Group 4 — fixture and tooling completeness

Tooling is where quotations quietly differ, and the FAT is the moment to count it. Two benches with the same tonnage can arrive with different tooling, and the missing half is bought later at spare-part prices — plus the days the machine stands idle waiting for it.

Group 5 — controls, records and data export

Group 6 — safety and packing

A one-day FAT agenda that covers the above

StepWhat happensResult recorded
1. Paper checkNameplate against order; documents present by name; voltage matchSerial number noted on the FAT sheet
2. Static checksOil, hoses, ten minutes running, no leaksLeaks: none / observed
3. CalibrationDisplayed pressure against reference gauge; relief setting notedReadings at two points on the range
4. FAT valve, shell testYour representative valve at 1.5 × PN, hold watched against a stopwatchHold time, curve screenshot
5. FAT valve, seat test1.1 × PN on the closed discHold time, verdict against the agreed acceptance factor
6. RecordsUSB export of the two runs, file opened on a laptopFiles named and archived
7. Tooling countPlates per DN band mounted and tried; spares countedPacking list signed
8. Open pointsAnything unresolved written down with an owner and a dateNothing ships on a verbal promise

Step 4 uses your valve, not the supplier's showcase piece. A showcase piece proves the machine can hold pressure; your valve proves the machine can test your valve — which is what you are actually buying. If you cannot attend, the same agenda runs live over video call, with the USB export shown on screen.

Frequently asked questions

Can a valve test bench be accepted remotely if I cannot visit the factory?

Yes, with structure. The supplier runs the agreed FAT agenda live over a video call: your representative valve is tested at the shell and seat pressures, the hold timer is watched against a stopwatch, and the test record with its time–pressure curve is exported to USB and shown on screen. Changxun standard benches ship with commissioning support by video call covering pressure calibration and acceptance settings, so remote acceptance follows the same format.

What is an acceptance factor on a test bench?

It is the tolerance applied to the hold: a pass is recorded when the pressure stays above the test pressure multiplied by the acceptance factor for the whole hold time, and a drop below it raises an alarm. Agree the factor before shipment — two benches with different factors will judge the same valve differently.

What tooling should ship with a valve test bench?

Sealing plates or grip jaws covering the whole ordered DN range, not only the first size — on the DFS2-600, blind plates for DN50-150, DN200-300, DN350-450 and DN500-600 plus extension rods and rod flanges — together with spare sealing elements, which are consumables. Count both at the FAT.

Which documents should I receive with the machine?

As a minimum: an English manual, a wiring diagram, and the PLC programme backup. Ask for them to be listed by name in the order confirmation rather than described generically as "documents", and verify each one is physically present at the FAT.

What valve should be used for the FAT test run?

A representative valve from your own production: the size that dominates your order volume, tested at its real shell and seat pressures — for a PN-rated valve, 1.5 × PN for the shell and 1.1 × PN for the seat. Testing a showcase piece proves the machine can hold pressure; testing your valve proves the machine can test your valve.

What should be settled before the machine is packed?

The open points from the FAT closed in writing, the tooling and spare-part list checked against the order, the FAT records exported from the USB port kept as the acceptance baseline, and the commissioning agenda for arrival agreed — what connects first, who supplies power and water, and when the acceptance settings are re-confirmed after transport.

Benches this agenda applies to

DFS2-600 · Dual station

  • DN50 – DN300 / DN350 – DN600
  • 0 – 7 MPa water
  • Pass/alarm against acceptance factor, USB export
View DFS2-600 →

SYJ-600SQ · Water + air

  • DN50 – DN600
  • 40 MPa water / 4 MPa air
  • 90 t clamp, one clamping for both media
View SYJ-600SQ →

WBD-600 · Horizontal

  • DN50 – DN600
  • 0 – 16 MPa water
  • 150 t end clamp, both ends fed
View WBD-600 →

ZZC2-200 · Automatic line

  • DN50 – DN200 gate valves
  • Strength / lower seal / upper seal sequence
  • Printed test records
View ZZC2-200 →

For the selection path from pressure to leakage class to layout to fixture, start at the valve pressure test bench buyer guide, then the test pressure chart, the leakage rate classes, and the clamping methods reference.

Ask for a FAT agenda with your quotation

Send your valve types, DN range and test pressure — the proposal includes the clamping method, the model and the FAT agenda, within 12 working hours.