CHANGXUN | Valve Test Equipment

Home / Valve Test Benches / Clamping methods

How a valve is clamped on a test bench — and why the fixture decides whether the result is valid

The pressure gauge cannot tell a seat leak from a leak at the sealing plate. Both reduce the pressure in the same closed volume. So the fixture — the blind plates, the grip jaws, the end cylinders — is not an accessory to the test, it is part of the measurement. This page compares the three ways a valve is held on a hydrostatic test bench, maps each one to the valve bodies it suits, and lists the fixture details worth confirming before you place an order.

Blind platesRadial grip jawsEnd clampingWeld-neck adapters

Get a quotation  Send your valve body type

Quick answer

Flanged gate, globe, ball valvesBlind plate + top clamp
Wafer or lug butterfly valvesRadial grip jaws or wafer adapters
DN350 – DN600, long face-to-face bodiesHorizontal end clamp
Butt-weld end valvesWeld-neck adapters
Mixed DN50 – DN600 in one shiftDual station, one range per station

Three jobs the fixture has to do at once

Every pressure test closes the valve body into a sealed volume, fills it, raises it to the test pressure and watches the pressure for a fixed hold time. The pressure acts on the inside of the body in every direction, including on the two faces where the fixture closes it. Those two faces carry the whole axial load of the test, and they are also where the fixture seals. A working fixture satisfies three conditions:

If any of the three is missing, the bench still produces numbers — they are just not numbers about the valve. The usual symptom is a good valve rejected twice and then passed on a different plate.

Method A — blind plates with vertical top clamping

The valve sits on a lower plate, a top cylinder closes it downward

Used on: SYJ-150, YSYJ-300, SYJ-600SQ, and the two stations of the SYJ2-300-600

The most common arrangement for flanged valves and fittings. Water enters through the centre of the lower plate, the top plate closes the upper flange, and the cylinder holds both plates against the valve. Plates are supplied in size bands and carry an elastomer seal on the face that bears on the flange.

Where it stops: a wafer or lug butterfly valve has no flange for the plate to bear on, and a butt-weld end valve has no flange at all. Both need a different fixture — a wafer adapter pair, or the weld-neck adapters that the YSYJ-300 is quoted with for welded-end valves.

Method B — horizontal end clamping

The valve lies on its axis and the cylinder closes it from the end

Used on: WBD-600

Same sealing principle as Method A, rotated 90 degrees and moved down to waist height. On the WBD-600 a 150-ton cylinder closes the valve between two end plates, and water is fed from both ends so the seat can be tested from either direction without re-clamping.

Where it stops: the working pressure ceiling follows the clamping tonnage, so a horizontal large-bore bench is quoted for the pressure band its cylinder can hold at DN600 — 0 – 16 MPa on the WBD-600 — not for the 40 MPa of a small-bore frame.

Method C — radial grip jaws with top assistance

The jaws close around the body; nothing is bolted to a flange

Used on: DFS2-600 (both stations)

The jaws move inward radially around the outside of the valve body while a top cylinder presses down to assist, so the valve is secured without bolting up a flange set. On the DFS2-600 water enters through the centre and vents through the top blind plate. The left station covers DN50 – DN300 with 80-ton grip clamping and a 60-ton top cylinder; the right station covers DN350 – DN600 with 126-ton grip clamping and an 80-ton top cylinder, both on one frame sharing one hydraulic power unit.

Where it stops: 0 – 7 MPa is the ceiling on this frame, and the reason is geometric — at DN600 the clamped area is large, so the pressure ceiling is matched to the cylinder forces. Large-diameter valves are normally PN2.5 – PN10, and a 1.5 × PN strength test stays inside that ceiling. If your work is DN50 at PN100, this is the wrong machine and a small-bore vertical bench is the right one.

Side-by-side comparison

CriterionBlind plate + top clampRadial grip jawsHorizontal end clamp
Seals againstFlange raised faceBody outside diameter, jaws + top assistEnd face of the body
Valve bodiesFlanged gate, globe, ball, plus fittingsButterfly, gate, welded-end bodies and fittingsButterfly, gate, ball, check, globe
Changeover inside a rangePlate pair per DN bandNone — jaws travel to the bodyPlate or adapter per DN band
Loading a DN600 bodyHoist over the lower plateHoist onto the stationTrolley at waist height
Long face-to-face bodiesNeeds frame heightTight for long bodiesNative fit
Seat test both directionsDepends on water routingDepends on water routingBoth ends fed
Typical machineSYJ-150, YSYJ-300, SYJ-600SQDFS2-600WBD-600

Which valve body needs which fixture

Valve bodyFixtureWhat to watch
Flanged gate / globe (ASME B16.5, EN 1092, GOST)Blind plate + top clampPlate face condition; confirm the flange standard and rating so the plate matches
Wafer butterflyRadial grip jaws or wafer adapter pairNo flange face — the plate must bear on the body face, not on air
Lug butterflyWafer adapter with through-bolts, or grip jawsLug ears take the load; check thread condition before clamping
Ball valve, long patternHorizontal end clampFace-to-face length; whether the seat test must run both directions
Check valveHorizontal end clampLong body; the disc has to be held closed for the seat test
Butt-weld end valveWeld-neck adaptersPipe schedule and weld prep geometry
Fittings (elbow, tee, reducer)Blind plate + adaptersCenter-to-face dimensions, not just DN

What ships with the machine, and what it costs you later

Fixture scope is where quotations quietly differ. Two benches with the same tonnage and the same pressure range can arrive with very different tooling, and the missing half is bought later at spare-part prices and at the cost of the days the machine stands idle waiting for it. The points worth writing into the order:

What to send us for a fixture-matched quotation

With those seven points we can name the clamping method, the tonnage and the pressure ceiling for your size band, and put them in writing with the quotation.

Frequently asked questions

Can I test a wafer butterfly valve on a bench with blind plates?

A wafer or lug butterfly valve has no flange face for the plate to seal against, so a plain blind plate will not close the body volume. It needs a wafer adapter pair that seals on the body faces, or a bench with radial grip jaws that close on the outside diameter, such as the DFS2-600. Tell us the body type when you ask for a quotation and the fixture is matched to it.

Can a worn sealing plate cause a false leak reading?

Yes, and it is the most common reason a good valve is rejected. The pressure drop is measured in one closed volume, so a leak at the plate seal and a leak through the seat look identical on the gauge. Inspect the plate faces in the daily check and keep spare sealing elements — re-test a failed valve on a fresh plate before scrapping it.

Do I need a separate sealing plate for every valve size?

No. Plates are supplied in size bands. The DFS2-600 ships with upper and lower blind plates for DN50-150, DN200-300, DN350-450 and DN500-600, so the full range is testable on delivery. A bench with radial grip jaws needs no plate change at all inside a station's range, because the jaws travel to the body diameter.

How do I test a butt-weld end valve?

With weld-neck adapters instead of flange plates. The adapter is machined to the pipe schedule and seals on the weld prep, so the valve is tested in the condition it will be installed. It is a standard option on the YSYJ-300 and can be quoted for the other vertical benches.

Which clamping method is fastest for mixed batches?

Radial grip jaws, because nothing is exchanged between sizes. On the DFS2-600 the two stations are permanently fitted with their own jaws and cylinders, so moving from a DN100 valve to a DN500 valve is a change of station, not a change of tooling.

How much clamping force does my valve need?

Enough to hold the end load with a margin, and the end load is the test pressure multiplied by the sealed area — it grows with the square of the diameter. That is why a large-bore machine is specified with high tonnage and a lower maximum pressure than a small-bore machine. Send the DN, the valve type and the test pressure and we will confirm the tonnage and the pressure ceiling for your size in writing.

Benches and the fixture each one uses

DFS2-600 · Grip jaws

  • DN50 – DN300 (80 t grip) / DN350 – DN600 (126 t grip)
  • 0 – 7 MPa water
  • Two stations, one power unit
View DFS2-600 →

SYJ-600SQ · Blind plates

  • DN50 – DN600
  • Water 40 MPa / Air 4 MPa
  • 90 t clamp, one clamping for both media
View SYJ-600SQ →

WBD-600 · End clamp

  • DN50 – DN600
  • 0 – 16 MPa water
  • 150 t cylinder, both ends fed
View WBD-600 →

YSYJ-300 · Blind plates / weld-neck

  • DN50 – DN400
  • Water 40 MPa / Air 0.8 MPa
  • 80 t top clamp
View YSYJ-300 →

For the selection logic from pressure to tonnage to station layout, read the valve pressure test bench buyer guide. For how the machine is loaded and where it stands, read horizontal vs vertical valve test bench.

Send your valve body types — we will name the fixture, the tonnage and the pressure ceiling

Flange standard, DN range, face-to-face length and test pressure are enough for a fixture-matched proposal: clamping method, model, datasheet and price within 12 working hours.

Request a quotation