CHANGXUN | Valve Test Equipment

Home / Valve Test Benches / Selection by DN

Valve test bench selection by DN — start with the bore, then check the two ceilings

Most enquiries open with the largest valve that will ever be tested. That is the right instinct and the wrong first question: the bore decides the frame, the daylight, the plates and the lifting, while the pressure class only decides the pump. This page runs the selection in the order that works — DN band first, then the two ceilings it has to fit under, then the span, the fixtures and the cycle time.

DN15 – DN600Span & plate sizeFlange adaptersCycle time

Get a quotation  Send your DN list

Quick answer

DN15 – DN150Vertical, 30-t clamp — SYJ-150, to 40 MPa water
DN50 – DN300, high classVertical, PLC, 80-t — ZSYJ-300A
DN50 – DN600, large boreHorizontal, 150-t — WBD-600, to 16 MPa water
Water + airSYJ-600SQ, 40 MPa water / 4 MPa air
Driven byBore first, then the highest class in that bore

Two ceilings every DN has to fit under

Every bench has a pressure ceiling in MPa and a size ceiling made of tonnage plus daylight, and the two pull in opposite directions. A DN25 valve at PN400 is tested at 60 MPa and needs a pump, a manifold and a gauge range most workshops never use — yet the valve weighs a few kilos and the plates are the size of a dinner plate. A DN600 valve at PN10 is tested at 1.5 MPa, a pressure a garden hose could nearly reach, yet the body is 0.78 m long, the plates are 780 mm across and the assembly is a crane job.

So read the DN band to fix the frame, then the highest class inside that band to fix the pump. If the top class breaks the frame, the answer is rarely a bigger bench: it is two benches, or an outside test house for the handful of extreme valves. The arithmetic behind the two ceilings — and why the separating force follows the sealed area rather than the gauge — is on the hydrostatic test pressure chart.

The size matrix: which bench for which DN band

DN bandWhat usually arrivesBench typeWhat the DN drives
DN15 – DN50Small gate, globe and ball valves, instrument valves, high classesVertical, single station, 30-t classReducing plates and a fine gauge; pressure is the limit, not size
DN50 – DN150General service gate, ball and butterfly valves, PN16 to PN250Vertical, 30–80-t class, manual or PLCOne plate set per DN and drilling; long gate bodies start to matter
DN150 – DN300The bulk of butterfly and gate valves in most workshopsVertical, 80-t class, PLCPlate weight becomes a two-man lift; handling needs a hoist
DN300 – DN400Gate valves with long face-to-face, large butterflyHorizontal, 150-t classDaylight: body length plus two plates plus ram travel
DN400 – DN600Large butterfly, gate and check valves; water and wastewater sizesHorizontal, 150-t classBed length, plate diameter, lifting, floor space, foundation
DN600 and abovePipeline valves, usually tested one at a timeBuilt to orderSpan, plate mass, fill volume, lifting

The band decides the frame; the class inside it decides the pump. A DN300 body at PN16 and the same body at PN250 can share a frame and cannot share a pump.

The envelope nobody quotes: daylight and plate diameter

Two dimensions decide whether a valve physically goes on a bench, and neither appears on a tonnage-based offer.

Fixtures: what makes the reading repeatable

The bench is the machine; the fixtures decide whether the result is trustworthy. Settle three of them before the order, because they are cheap at the factory and awkward afterwards.

Seat type is the fourth. A resilient-seated valve is judged on bubbles or on zero visible leakage and needs a controlled air circuit; a metal-seated valve is judged against a rate class. The classes and the counting method are on the leakage rate classes page, and how the force is generated — ram, tie rods or self-energising seal — is on the clamping methods page.

Cycle time and the station count

Size sets the handling time, and handling is where a manual bench loses its day. One DN200 valve at PN16 takes roughly 8–10 minutes from loading to drain on a manual vertical bench: clamp, fill, vent, shell hold, two seat holds, drain, unload. The pressure holds are a small part of that.

Run the arithmetic on your own volume: fifty valves a day at ten minutes is more than eight hours of operator time before anything goes wrong, and a batch of DN500 valves is slower because each one needs the hoist. Two things change the number — a second station on the same frame, which shares pump and tank and lets one valve soak while the other is loaded, or a PLC bench, which times the holds and logs pressure and leakage per serial. If your customers ask for an inspection and test plan, that log is usually a requirement rather than a convenience; the buyer guide covers the control and record side.

Leave the DN range open

Workshops rarely stay inside the range they bought for. Two habits keep the door open without paying for capacity you do not need yet. Buy the frame one band up and the plates as you go: the frame, pump and tank are the expensive parts, plates are a fraction and can be added in any year. And ask for a horizontal conversion before ordering rather than after — some vertical benches take an optional horizontal frame sharing the same pump, while retrofitting means moving the machine and re-piping the manifold.

If the mix is genuinely wide — small high-class valves plus large low-class ones — the honest answer is two benches or two stations, because no single frame covers DN25 at PN400 and DN600 at PN10 without compromise. The test bench range lists the four frames we build most, and the selection usually lands on one of them.

SYJ-150 · DN15 – DN150

  • Water 0 – 40 MPa
  • 30-ton clamping
  • Small bore, high class
View SYJ-150 →

ZSYJ-300A · DN50 – DN300

  • 1.6 – 40 MPa
  • 80-ton clamping, PLC
  • The general-purpose frame
View ZSYJ-300A →

WBD-600 · DN50 – DN600

  • Water 0 – 16 MPa
  • 150-ton end clamp
  • Long bodies, large bore
View WBD-600 →

SYJ-600SQ · DN50 – DN600

  • Water 40 MPa / air 4 MPa
  • 90-ton clamping
  • Bubble count for resilient seats
View SYJ-600SQ →

Two worked answers. DN15–DN150 valves up to PN250 land on the SYJ-150, where pressure is the hard part and the frame is small. DN300–DN600 gate and butterfly valves at PN10–PN16 land on the WBD-600, where pressure is easy and daylight, plate mass and the hoist are the whole problem. When classes vary and valves arrive in batches, the ZSYJ-300A is the usual compromise.

Questions we get asked about bench size

What test bench do I need for DN600 valves?

A horizontal bench with about 1.2 m of clear daylight, a 150-tonne class clamp and a hoist. The WBD-600 covers DN50–DN600 to 16 MPa water. Above that class the frame and plate thickness change, so send the class before assuming a standard model covers it.

Can I test a DN50 valve on a DN600 bench?

With a set of reducing plates, yes — and only with them. Clamping a small valve between large plates puts the seal far from the bolt circle, the plate deflects under pressure, and a seat leak looks like a seal leak.

Do butterfly and gate valves need different benches?

Same bench, different fixtures. Wafer butterfly valves are short and need spacer sleeves so the disc clears the plate; gate valves are long and set the daylight requirement. A bench bought for DN600 gate valves tests DN600 butterfly valves comfortably.

Is DN or pressure class the bigger cost driver?

DN. It sets the frame, the daylight, the plate diameter, the clamp and the lifting. Class mainly sets the pump, manifold wall thickness and gauge range — which is why a small high-class bench costs far less than a large low-class one.

How much floor space should I allow?

About 4 m × 1.2 m for a DN600 horizontal bench, plus 800 mm of loading clearance and room for a trolley. A DN300 vertical bench needs roughly 1.6 m × 1 m, plus the control cabinet.

One large bench or two smaller ones?

One bench plus reducing plates, unless small valves are most of your volume. If small and large sizes both run daily, two stations on one frame usually beats two machines, because pump, tank and controls are shared.

Send the DN list and the highest class — we will map it to a frame, a plate set and a layout drawing

Give us the sizes, the classes and the valve types you see in a month. You get a model recommendation, the fixture list with drilling standards, a footprint drawing and a price within 12 working hours.

Request a quotation