Water is the default test medium because it stores almost no energy and its leaks are visible; air is used only where the order demands a gas leg — gas service, dry systems, or a specification that names it. This page separates what the medium genuinely changes (detection, gauges, bench hardware, safety planning) from what it never changes (the 1.5 × / 1.1 × multiples, the acceptance class, the envelope of the machine).

Hydrostatic testingPneumatic seat legsDual-purpose benchesShell 1.5 × / seat 1.1 ×

Get a quotation  Send your valve list

Quick answer

QuestionShort answer
Default medium?Water — low stored energy, visible leakage, safe at 1.5 × shell pressures
When is air required?Gas service (API 6D gas seat leg), no-residue specifications, or the order names it
Do criteria change on air?No — 1.5 × / 1.1 × and the class come from the cited edition either way
What must the bench add?An air circuit with its own regulator and a low-range gauge; water-only frames cannot run gas legs
Which models carry air?SYJ-600SQ up to 4 MPa, YSYJ-300 up to 0.8 MPa, WBD-400 up to 20 MPa (DN200–450)

The medium changes the hardware and the detection; the judgement comes from the order.

Water is the default — and the physics is why

Most valve test benches you will ever see are water machines, and that is not an accident of habit. Water is close to incompressible: a water-filled body stores very little energy even at the top of the range, so a shell test at 1.5 × the rating — the highest-pressure leg on any order — is executed on water, at pressures that reach 40 MPa on the small-bore end of the current range. A failure on a water leg announces itself as a jet and a puddle; the same failure on a compressed-gas leg stores energy in the gas itself, which is why gas legs are kept at low pressures and why a pneumatic strength test is not a routine bench job (more on that below).

Water also suits the judgement work. Seat leakage shows up as a wet line, a drip or a visible film on the downstream side, and the shell leg dries off without ceremony. Where the order allows the seat test on water — API 598 does, for example — many workshops run the whole sequence on water because the leak is easier to see and the record is easier to write. The hydrostatic procedure page shows what is recorded leg by leg on water.

When the order forces air

Three situations put a gas leg on the order, and none of them is the operator's preference. First, valves for gas service: pipeline orders written to API 6D include a low-pressure gas seat test, at roughly 0.5–0.7 MPa depending on the edition and the valve — the exact figure comes from the order. Second, specifications where a water residue is unacceptable: valves that go into gas or oxygen service, or instruments upstream of dry systems, often carry an explicit gas-test clause precisely so that no water is left inside. Third, the customer's own purchase order simply names the seat test on gas.

What does not change with the medium is the multiple. The seat leg runs at 1.1 × the rating of the highest class tested on that medium, and the shell at 1.5 ×, from the cited edition — GB/T 13927-2022, API 598, API 6D, ISO 5208 or EN 12266-1 — whether the leg is filled with water or air. Air does not soften the acceptance criteria; it changes the hardware, the detection method and the safety envelope around the bench. The standard selection page maps the five common standards onto those legs.

What air changes in detection and judgement

On a water leg, judgement is visual: a wet line, a drop, a film. On a gas leg the leak is invisible, so detection moves to two methods that both have to be planned for. The first is a soap solution brushed over the downstream joints and the seat area — bubbles are the leak. The second is observation of the gauge: on a hold, pressure decay on a gas leg is read against the tolerance the order allows. Both methods judge against the same acceptance class the order cites; the leakage classes page explains how the letters map to rates.

One practical consequence matters more than any catalogue figure: a gas leg runs at low absolute pressure, and a 40 MPa gauge is useless for reading it. At 1.6% of full scale, the reading error of a 40 MPa gauge is about 0.64 MPa — larger than the whole gas seat leg it is supposed to measure. Every bench that runs gas legs therefore carries a low-range gauge on the air circuit, and the record is read from that gauge, not from the water one.

What air changes in the bench hardware

A bench that runs both media is not a water bench with a compressor bolted on. The air circuit needs its own regulator and its own low-range gauge, a fill-and-vent path that can be dried before the gas leg, and drainage so the water leg's residue does not migrate into the gas record. The water circuit needs its pump, its high-range gauge and its blind plates; the two circuits meet at the clamping fixture and nowhere else. This is why the water/air combination is an explicit line in the model tables below, and why a water-only bench cannot run a gas seat leg at any price.

The air circuits on the current range, with the figures we publish on the model overview:

ModelAir circuitWhat it covers
SYJ-600SQup to 4 MPaGas seat legs into the PN16–PN25 band on small-to-mid bores (1.1 × arithmetic), on a 40 MPa water frame
YSYJ-300up to 0.8 MPaPN6 gas seat legs — 1.1 × of PN10 is 1.1 MPa, so the circuit stops there
WBD-400up to 20 MPa (DN200–450)High-pressure gas legs on the horizontal frame, per the cited standard
SYJ-150no air circuitWater-only small-bore work at up to 40 MPa
ZSYJ-300Ano air circuitWater-only vertical work, 1.6–40 MPa

Models not listed in this table may or may not carry an air circuit depending on configuration — confirm per model against your valve list before ordering. The full envelope table (DN ranges, water pressures, clamping) is on the model overview and is repeated on every guide page; the medium does not change it.

Safety: why the legs are split the way they are

The split between a 1.5 × water shell leg and a low-pressure gas seat leg is not a convention — it follows from the stored energy of the two media. Water barely compresses, so the energy behind a shell-test failure stays low even at 40 MPa. Air compresses by volume: the same pressure in the same cavity stores far more energy, and a gas failure releases it as a burst rather than a jet. That is why the standards that call for gas legs specify them at low absolute pressures, and why a pneumatic strength test of a large body is a special procedure carried out behind barriers, with the area cleared — not a routine job on a bench floor.

Two rules follow for whoever operates the bench. Do not swap the medium to make a number pass: if the shell leg fails on water, running it on air does not fix the valve, it only makes the record harder to defend. And where a standard's own clause allows a reduced factor for pneumatic testing, that reduction is applied because the standard says so for that test — never as an operator's preference on the floor. The supplier checklist page lists the questions that expose how a vendor actually runs these legs.

Choosing when the order allows both

Where the standard leaves the seat medium open, most shops run seats on water for visibility and keep the gas circuit for the orders that demand it. That is a scheduling choice, and a legitimate one — but it has to be made per order, not per habit, because the gas clause usually arrives with the customer's quality group attached. The bench you buy should be sized for the hardest standard-and-size pair you will ever test, including the air requirement at the highest class you will run on gas; the standard selection page shows how that pairing drives the choice, and the selection by DN page sizes the frame around your diameter band.

Where the gas work is high-pressure — the 20 MPa circuit on the WBD-400 band, for example — the fixture questions from the safety valve page and the horizontal layout page apply unchanged, because the envelope is a property of the frame, not of the medium in the lines.

Boundaries — what a medium choice does not do

Changing the medium does not change the envelope, the multiples or the acceptance class. Shell stays at 1.5 × and seat at 1.1 × from the cited edition; the class letters come from the order, not from the gauge you read them on. A passed leg on air is not a promise that the valve will not leak in service — no test result is. Closing-torque measurement, fire-safe qualification (API 607 / API 6FA) and fugitive-emission testing (ISO 15848) are separate exercises in every medium. And a water-only bench cannot be upgraded into a gas-capable one by swapping gauges: the air circuit is built hardware, which is also why it is a line item in the quotation rather than an accessory.

Frequently asked questions

Is a hydrostatic test always safer than a pneumatic one?

At the same pressure and cavity volume, yes: water is close to incompressible and stores very little energy, while compressed gas stores enough to burst the body. That is why strength testing at 1.5 × is done on water and gas legs are specified at low absolute pressures. A pneumatic strength test is a special procedure behind barriers, not a routine bench job.

Can one bench run the shell on water and the seat on air?

Yes — that is exactly what the water/air dual-purpose models are for. The sequence follows the order: shell at 1.5 × on water, seat at 1.1 × on whichever medium the order names, each leg read on the gauge sized for it. The two circuits meet at the clamping fixture and nowhere else.

What air pressure does an API 6D gas seat test need?

The low-pressure gas seat leg runs at roughly 0.5–0.7 MPa depending on the edition and the valve; the binding figure is the one on the order. The circuit and the low-range gauge must reach 1.1 × the rating of the highest class tested on gas. The API 6D page walks the sequence leg by leg.

Why does a 40 MPa gauge read nothing on a PN10 air leg?

Because the leg sits at about 1.1 MPa and the gauge's reading error at 1.6% of full scale is about 0.64 MPa — over half the leg's target. Gas legs are read on a low-range gauge dedicated to the air circuit, and the record carries that gauge's calibration trail.

Which Changxun benches carry air circuits?

The SYJ-600SQ (up to 4 MPa), the YSYJ-300 (up to 0.8 MPa, which covers PN6 gas seat legs), and the WBD-400 (up to 20 MPa on DN200–450). The SYJ-150 and ZSYJ-300A are water-only; other models are confirmed per configuration against your valve list.

Does testing on air change the pass criteria?

No. The multiples — shell 1.5 ×, seat 1.1 × — and the leakage class come from the cited edition of the standard on the order. Air changes the detection method (soap solution, gauge hold) and the hardware, not the judgement.

Send the valve list with the medium column filled in — which legs must run on gas, and at what class — and we will match a frame with the right circuits and gauge ranges to it: request a recommendation.