ASME class valve test pressure — 150 to 2500 in bar, MPa and psi
A pressure class on a valve order is an index into a rating table, not a number of psi. This page turns the six common classes into the two pressures a bench actually has to hold — shell at 1.5 × and seat at 1.1 × the 38 °C rating — and lines those figures up against the pressure envelope of the machines we build, so you can see where each class stops.
Quick answer
| Class | Rating 38 °C | Shell 1.5 × |
|---|---|---|
| 150 | 19.6 bar / 285 psi | 29.4 bar · 2.94 MPa |
| 600 | 102.1 bar / 1,480 psi | 153.2 bar · 15.3 MPa |
| 1500 | 255.3 bar / 3,705 psi | 383 bar · 38.3 MPa |
| 2500 | 425.5 bar / 6,170 psi | 638 bar · 63.8 MPa |
Carbon steel, material group 1.1, at 38 °C (100 °F). The last row is past the envelope of every catalogue model — see the table further down.
The class number is an index, not a pressure
Class 300 does not mean 300 psi, and Class 1500 does not mean 1,500 psi. The number is a row label in the pressure–temperature tables of ASME B16.34: you take the class, the body material group and the design temperature, and the table gives you the allowable working pressure. At 38 °C the carbon steel values are the ones in the table above; at 300 °C the same Class 150 body falls to 10.2 bar, and at 425 °C to 5.5 bar. The class does not change — the allowable pressure does.
Two consequences matter for a test bench, and both of them are arithmetic rather than opinion:
- The test pressure comes from the 38 °C figure. API 598 sets the shell test at 1.5 × and the seat test at 1.1 × the pressure rating at 38 °C. A Class 150 valve bound for 300 °C steam is still shell-tested at 29.4 bar, not at 1.5 × its 10.2 bar service rating.
- What the bench must hold is set by the valve, not by the medium. Water, steam, gas, sour service — the class decides the number. That is why one bench has to cover several classes across a size range, and why the DN range and the class range have to be quoted together.
If your drawings and orders run on the European system instead, the equivalent figures are in the hydrostatic test pressure chart, which goes PN10 to PN400 with the same 1.5 × / 1.1 × logic, and in the by-standard page, which shows how API 598, API 6D, ISO 5208, EN 12266-1 and GB/T 13927 differ.
All six classes, both test pressures
| Class | Rating at 38 °C | Shell 1.5 × | Seat 1.1 × |
|---|---|---|---|
| 150 | 19.6 bar · 285 psi | 29.4 bar · 2.94 MPa · 426 psi | 21.6 bar · 2.16 MPa · 313 psi |
| 300 | 51.1 bar · 740 psi | 76.7 bar · 7.67 MPa · 1,112 psi | 56.2 bar · 5.62 MPa · 815 psi |
| 600 | 102.1 bar · 1,480 psi | 153.2 bar · 15.3 MPa · 2,221 psi | 112.3 bar · 11.2 MPa · 1,629 psi |
| 900 | 153.2 bar · 2,220 psi | 229.8 bar · 23.0 MPa · 3,333 psi | 168.5 bar · 16.9 MPa · 2,444 psi |
| 1500 | 255.3 bar · 3,705 psi | 383 bar · 38.3 MPa · 5,554 psi | 280.8 bar · 28.1 MPa · 4,073 psi |
| 2500 | 425.5 bar · 6,170 psi | 638 bar · 63.8 MPa · 9,257 psi | 468 bar · 46.8 MPa · 6,789 psi |
Shell and seat columns are arithmetic on the 38 °C rating (1.5 × and 1.1 ×), rounded; psi = bar × 14.504. Values are for ASME B16.34 material group 1.1 at 38 °C. Check your own copy of the standard and your customer's specification before you write a number into a test report — an edition difference or a company spec can move the figure.
Where each class meets our envelope
Our models quote a maximum water pressure of 40 MPa at the small-bore end of their DN range, and less at the large-bore end. Put that against the shell column and the picture is simple: the bench covers Class 150 to Class 1500 in the small and middle sizes, and stops before Class 2500 at any size.
| Class | Shell test | Seat test | What covers it |
|---|---|---|---|
| 150 | 2.94 MPa | 2.16 MPa | Every model, including the compact SYJ-150 (DN15–DN150, 0–40 MPa, 30 t) |
| 300 | 7.67 MPa | 5.62 MPa | Any 16 MPa-and-above model across its DN range, e.g. WBD-600 (DN50–DN600, 0–16 MPa, 150 t) |
| 600 | 15.3 MPa | 11.2 MPa | 40 MPa models, and the 0–16 MPa WBD-600 just at its ceiling — worth checking the size, not only the pressure |
| 900 | 23.0 MPa | 16.9 MPa | 40 MPa models only: ZSYJ-300A, YSYJ-300, SYJ-600SQ |
| 1500 | 38.3 MPa | 28.1 MPa | The same 40 MPa models, at the small-bore end of the range; the margin to 40 MPa is 1.7 MPa |
| 2500 | 63.8 MPa | 46.8 MPa | Not a catalogue model. Both figures are above a 40 MPa bench, so this is a special build, quoted case by case |
Two things this table does not say. It does not say a 40 MPa bench tests a DN600 valve at 40 MPa — the pressure envelope closes as the bore opens, which is the whole subject of the DN-first selection table. And it does not say the frame is the only limit: at 38.3 MPa the clamping force has to hold a blind plate that is being pushed outward, which is why the 40 MPa models carry 80–90 t of clamp rather than 30 t.
Why the pressure envelope closes as the bore opens
The pressure a bench can hold is one number; the force that pressure puts on the blind plate is another, and it grows with the square of the bore. Thrust is pressure × the area the pressure acts on, so at the Class 900 shell figure of 23.0 MPa:
| Bore | Area of the bore | Thrust at 23.0 MPa |
|---|---|---|
| DN50 | 0.00196 m² | 45 kN · about 4.6 t |
| DN100 | 0.00785 m² | 181 kN · about 18 t |
| DN200 | 0.0314 m² | 723 kN · about 74 t |
| DN300 | 0.0707 m² | 1,626 kN · about 166 t |
Area = π / 4 × bore²; thrust in kN = pressure in MPa × area in m² × 1,000. Rough figures for sizing a conversation, not for a design calculation — the plate, the seal and the frame each take their share.
This is the arithmetic behind the sentences “40 MPa at the small-bore end” and “80 to 90 t of clamping”. A DN300 valve at Class 900 is a different problem from a DN80 valve at Class 900, even though the test pressure is identical — and it is why a bench is never specified by pressure alone.
Four traps that come from mixing scales
1. PN40 is not Class 300
PN40 means 40 bar. Class 300 means 51.1 bar at 38 °C. A Class 300 valve tested to the PN40 shell figure (1.5 × 40 = 60 bar) is being tested at 60 bar when the standard asks for 76.7 bar — under-tested by 16.7 bar, on a valve that will pass and be reported as passed. The reverse mistake exists too: a PN16 valve tested to a Class 150 routine is over-tested at 29.4 bar against a 24 bar requirement. Both directions come from treating two different scales as one.
2. Assuming the test pressure falls with service temperature
It does not. API 598 takes the test pressure from the 38 °C rating, so a Class 150 valve is shell-tested at 29.4 bar whether it goes into cooling water or into 300 °C steam. If your customer's specification says “1.5 × design pressure” instead, the number can be lower than the class figure — the purchase order governs, and we test to what is written on it, not to what the class implies.
3. Reading a Class 150 seat test on a 40 MPa gauge
A 0–40 MPa gauge at 1.6% of full scale carries an uncertainty of ±0.64 MPa. At the Class 150 seat point of 2.16 MPa that is about ±30% of the reading; at the shell point of 2.94 MPa, about ±22%. The gauge is fine and the test is meaningless. This is the arithmetic behind dual-gauge benches: one gauge for the high classes, a low-range gauge for the low ones, so the pointer works in the upper half of its scale. It is also why the same valve tested on two benches can produce two different verdicts without either operator doing anything wrong.
4. Testing the seat at shell pressure
The seat test is 1.1 ×, not 1.5 ×. Running a soft-seated valve up to the shell figure to “save a step” presses the seat far past its design differential: an EPDM or PTFE seat can extrude or take a set, and the valve then fails the tightness check for a reason the bench created. The two tests are separate pressures for a reason, and the sequence matters as much as the numbers — the test procedure page sets out the order.
When the datasheet is in psi
Three conversions cover almost every RFQ that arrives in mixed units:
- 1 MPa = 10 bar = 145.04 psi
- bar to psi: multiply by 14.504 — 76.7 bar = 1,112 psi
- psi to MPa: divide by 145.04 — 1,500 psi = 10.34 MPa
The trap is a datasheet that quotes a round number in psi, such as 1,500 psi, next to a class that requires more. 1,500 psi is 10.34 MPa, which sits between the Class 300 shell figure (7.67 MPa) and the Class 600 one (15.3 MPa) — so it is not a class figure at all, it is a design pressure somebody converted. Ask which one it is before the bench is specified; the difference decides whether a 16 MPa model is enough or a 40 MPa model is needed.
Hold time is set by size, not by class
The pressure comes from the class; the hold time does not. In API 598 the minimum duration of the shell and seat holds is tied to the valve size — a small bore is held for seconds, a large bore for minutes — so a DN50 Class 900 valve and a DN300 Class 150 valve are held for quite different times even though the first one is tested far harder. Take the duration from the edition of the standard you are working to, and set it on the PLC rather than on the operator's watch: a timed hold is the difference between a record that survives an audit and one that does not.
A mixed order, worked through
Most workshops do not buy for one class. Take a repair shop whose order book looks like this: Class 150 gate valves DN50–DN300, Class 600 ball valves DN50–DN150, Class 900 globe valves DN50–DN100.
- Highest shell pressure: 23.0 MPa, from the Class 900 globe. The bench has to hold that, so the 40 MPa models are the only candidates and the 0–16 MPa WBD-600 is out of the running whatever its bore range.
- Lowest seat pressure: 2.16 MPa, from the Class 150 gate. Together with the 23.0 MPa ceiling this is what specifies the gauge set — a high-range gauge and a low-range one, not a single 0–40 MPa dial.
- Clamp check: the hardest push is not the highest pressure, it is the largest plate — DN300 at 2.94 MPa puts about 21 t on the plate, DN100 at 23.0 MPa about 18 t. Both sit comfortably inside the 80–90 t clamp of the 40 MPa models, which is the point at which a size band can be quoted from a catalogue rather than engineered.
Change one line of that order book — a DN300 valve at Class 900 instead of Class 150 — and the thrust goes from 21 t to about 166 t. Same bench pressure, different machine. That is the single most common reason a quotation has to be reworked after the first enquiry: the class was quoted, the size was not.
What to put in the RFQ
- Class per valve type, not one class for the whole order — gate valves at 150 and a ball valve at 900 on the same bench is a normal request, and it changes the gauge set.
- The size band that goes with each class. Pressure and bore together decide the frame; either one alone does not.
- The standard and the edition you are testing to: API 598, API 6D, ISO 5208, EN 12266-1, GB/T 13927. The 1.5 × / 1.1 × basis is common to them, the hold times and the acceptance criteria are not.
- Whether air is needed as well as water, and at what pressure — a water-only bench and a water-plus-air bench are different machines.
- The gauge ranges you want: the highest shell pressure on the order and the lowest seat pressure. Those two numbers specify the dual-gauge set.
- The record format your customer accepts — printed curve, CSV, or both. See test data export for what can be written out.
The quotation side — how the twelve lines of a bench quotation are built, and what moves the lead time — is on the price and lead time page. The order of the work on the shop floor is on the valve test bench hub.
Boundaries
This page is arithmetic on published class ratings, not a substitute for the standard. Your edition of ASME B16.34, your customer's specification and the purchase order govern the number that goes into a test report.
We build and quote the bench. We do not rate the valve, we do not certify it, and we do not issue an acceptance verdict — that belongs to your quality procedure and, where required, to a recognised laboratory. Class 2500 is outside every catalogue envelope on this page and is quoted as a special build only.
Where a class and a size both sit at the edge of an envelope, the envelope does not move: a 40 MPa bench does not become a 63.8 MPa bench because the order needs one.
Questions we get on class-based testing
Is a Class 300 valve the same as PN40?
No. Class 300 is 51.1 bar at 38 °C; PN40 is 40 bar. The shell test follows: 76.7 bar for Class 300, 60 bar for PN40. They are close enough to be confused on a drawing and far enough apart to fail an audit.
What is the shell test pressure for a Class 600 valve?
153.2 bar, which is 15.3 MPa or 2,221 psi — 1.5 × the 102.1 bar rating at 38 °C. The seat test on the same valve is 112.3 bar, or 11.2 MPa.
Can your bench test Class 2500 valves?
Not from the catalogue. Class 2500 shell is 638 bar, 63.8 MPa, which is above the 40 MPa ceiling of our models; the seat test alone (46.8 MPa) is above it. That is a special build and is quoted case by case rather than listed as a model.
Do I test at the class rating or at the design pressure?
Whichever your standard and purchase order say. API 598 uses 1.5 × the 38 °C rating; some company specifications use 1.5 × the design pressure, which is usually lower. The bench does not choose — the order does, and the difference is worth settling before the valve is mounted.
Why does my bench have two gauges?
Because one gauge cannot serve both ends of the range honestly. A 0–40 MPa gauge at 1.6% of full scale is ±0.64 MPa, which is about ±30% of a Class 150 seat reading. The low-range gauge keeps the pointer in the part of the scale where the reading means something.
Does the test pressure change for a stainless body?
At 38 °C, no: for Class 150 to 1500 the group 2.2 (CF8M / F316) ratings in the same table coincide with the carbon steel figures used here, so the test pressures are the same. Above 38 °C the two materials de-rate at different rates, which is a design question rather than a bench one.
Tell us the classes on your orders, the DN range that goes with each, and the standard you test to. You get a model recommendation, the pressure envelope for that size band, the fixture drawing and a price within 12 working hours.