Home / Valve Test Benches / SYJ-600
SYJ-600 Vertical Valve Test Bench — DN50 to DN600, water to 40 MPa
The SYJ-600 is the base 600-series vertical bench: twin columns and a single crossbeam, a ø200 mm top ram with 90 tons of clamping force, and a table that slides out so the valve is loaded outside the frame. Butterfly, gate, welded-end valves and pipe fittings from DN50 to DN600 on one frame, at hydrostatic pressures up to 40 MPa.
At a glance
| Model | SYJ-600 |
|---|---|
| Valve size range | DN50 – DN600 |
| Water test pressure | 0 – 40 MPa (test limit 62 MPa) |
| Air test (option) | 4 MPa — that configuration is the SYJ-600SQ |
| Clamping force | 90 ton, ø200 mm ram, 350 mm stroke |
| Max daylight | 800 mm; face-to-face 200 – 800 mm |
How it works
The table slides out, the valve is set on the lower blind flange and centred, then the table is pushed back in. The top ram comes down until the upper blind flange seats on the flange face; rubber sealing strips in both flanges seal the joint, so the harder the pressure pushes, the tighter the seal. The low-pressure pump fills the body, air is bled from the top flange, then the high-pressure pump raises the pressure to the set value, stops automatically and the hold timer starts; a lamp and buzzer signal the end of the hold. Release the water pressure first, then lift the ram — the hydraulic circuit is interlocked so the ram cannot open while the body is still under pressure.
Two things on this frame matter more than the headline pressure. First, the table moves: a DN600 body is positioned outside the frame instead of being threaded between two columns. Second, the machine has separate inlets to the upper and lower cavity, so the seat can be tested from either side without unclamping the valve and starting over — on a repair bench that is where the time actually goes.
Specifications
| Structure | Vertical, twin columns, single crossbeam, top ram clamping, sliding table |
|---|---|
| Size range | DN50 – DN600 |
| Water test pressure | 0 – 40 MPa; machine test limit 62 MPa (nominal 40 × 1.55) |
| Air test | 4 MPa, requires shop air; this option is the SYJ-600SQ |
| Top ram | ø200 mm, 90 ton clamping force, 350 mm stroke, extension rod available |
| Face-to-face (valve length) | 200 – 800 mm, custom on request |
| Max flange diameter | 940 mm |
| Clearance between columns | 950 mm |
| Max daylight | 800 mm |
| Hydraulic system | 31.5 MPa max, 80 L of 46# hydraulic oil; booster pump 10 MPa max |
| Valves and piping | Stainless steel high-pressure ball valves, seamless stainless tubing |
| Footprint | 2620 × 1390 × 2200 mm (L × W × H) |
| Weight | approx. 2 t |
| Standards | Shell and seat tests to API 598, GB/T 13927, ISO 5208 |
| Warranty | 12 months from delivery, operator error excluded |
Figures follow the machine manual. Pressure gauges are an option (single gauge standard, dual gauge quoted separately for easier reading at low pressure); they do not change the pressure capability above.
Four 600-series configurations — pick by the job, not by the number
Four machines carry a 600 in the model name and they solve four different workshops. Choosing on price alone usually ends in either a bench that cannot clamp the valve or one that is bigger than the work needs.
| Model | Clamping | Range | Choose it when |
|---|---|---|---|
| SYJ-600 (this page) | Top ram, 90 t | DN50–600, water 0–40 MPa | Hydrostatic shell and seat tests only, budget first |
| SYJ-600SQ | Top ram, 90 t, plus air circuit | DN50–600, water 0–40 MPa, air 4 MPa | Water test then air tightness on the same clamping, low-pressure seat check with its own record |
| SYJ-600M | Four hydraulic jaws, 126 t | DN350–600, 0–10 MPa | Always large bore, modest class (PN10–PN16), body has to be held from the side |
| WBD-600 | End ram 150 t + 3-point 100 t | DN50–600, pressure by class | Long bodies, ball valves, big gate valves — no lifting onto a table |
Three questions settle it: the largest DN (vertical or horizontal), whether an air tightness test is needed (base model or SQ), and how high the class is (top ram or jaw clamping).


Beyond DN600 — four-column frames, built to the drawing
Above DN600 the blind flange is not the only thing that grows: the axial load is pressure times area, so the frame, the clamping cylinders and the loading method all change. We move to a four-column frame — four columns instead of two, clamping and blind flanges sized to the body, loading from the end rather than from above — for DN600 to DN1400. These are not catalogue machines: we work from your largest valve drawing and the standard you test to, size the clamping to suit, and quote against the drawing. The pressure rating stays nominal 40 MPa, test limit 62 MPa.
Questions buyers ask before ordering
Can the SYJ-600 do an air test?
Not in base form. Water and air on one bench is the SYJ-600SQ: same frame, plus water and air circuits, 4 MPa air, and it needs shop air on site.
Does DN600 really reach 40 MPa?
The pump and hydraulics are rated for it — nominal 40 MPa, test limit 62 MPa. The real limit is clamping: at DN600 and 40 MPa the axial load on the blind flange is around 1,130 tonnes. In practice a DN600 valve is usually PN10–PN16, so the test pressure is set to the class rather than to the ceiling. Tell us the largest DN and the standard, and the clamping is confirmed in the offer.
One bench for DN50 and DN600?
Yes. Blind flanges are swapped to the flange pattern, 200–800 mm covers short butterfly bodies through long gate bodies, and an extension rod takes up the height on small valves. Longer bodies are built to order.
How many valves per shift?
Load, clamp, fill, pressurise, hold, release — about a minute per small valve of handling. Hold time follows the standard: API 598 shell test runs from 1 to 5 minutes by size (5 minutes for DN350–600). For volume work, dual-station and PLC machines let one operator watch the curve instead of the clock.
Can it produce a test record per valve?
The base model is push-button, gauge and a paper log. For a file per valve — pressure curve, hold time, operator, valve ID, exportable as CSV or PDF into the job pack — specify the PLC touch-screen version (model number with the Z prefix).
Send your valve type, size range (DN) and required test pressure. We reply within 12 working hours with a model recommendation, datasheet and price.
What this model is quoted on, and which options move the number: valve test bench price by model.
Related pages
- SYJ-600SQ water and air bench — the same frame with an air circuit for 4 MPa tightness tests.
- SYJ-600M jaw-clamping bench — DN350–600 held from the side, 126 tons.
- WBD-600 horizontal bench — large bodies rolled in, not lifted.
- Selection by DN — plate size, daylight and clamp force by size band.
- Test pressure by class — where each PN/Class lands, and why 40 MPa is a small-bore figure.
- Datasheets and FAQ.