ZSYJ-300A - Automatic Valve Pressure Test Bench

Vertical, top clamping cylinder, full automatic test cycle
Changxun Machinery
Nanjing, China
ren@zbcxhb.net

DN50 - DN300 / up to 40 MPa

Automatic
Valve size rangeDN50 - DN300
Test pressure1.6 - 40 MPa water, final pressure set per requirement
Air testManual air test circuit
ClampingTop cylinder o180, maximum clamping force 80 t, stroke 350 mm
StructureVertical frame, single top cylinder presses the valve onto the fixed table
Test cycleWater filling, air purging, clamping, pressurising and release run as one automatic cycle
LoadingUpper beam rotates 90 degrees so the valve can be loaded from the side
RecordingPressure curve on screen, record exported as CSV file
MediumWater, recirculated from the built-in tank

Applied standards

Pressure note. 40 MPa is used on the small end of the size range. On DN250 - DN300 the pressure actually applied is set by the valve class, and the clamping force is calculated together with the pressure you need. Send the size and class and the configuration is confirmed in writing.
ZSYJ-300A data sheethttps://www.zbcxhb.net/en/price.html

SYJ-600SQ - Water and Air Valve Test Bench

Twin column, single beam, top cylinder, movable worktable
Changxun Machinery
Nanjing, China
ren@zbcxhb.net

DN50 - DN600 / water 40 MPa / air 4 MPa

Semi-automatic
Valve size rangeDN50 - DN600
Test pressureWater 0 - 40 MPa; air test 4 MPa
ClampingTop cylinder o200, maximum clamping force 90 t, stroke 350 mm
StructureVertical, twin column, single upper beam, top cylinder presses down
WorktableMovable - the table runs out of the frame, so the valve is loaded without a crane at the frame
Water pathsInlet at top and bottom; upper and lower chamber are pressurised separately, no second clamping
OutputExternal high pressure outlet for a second test point
MediumWater for the pressure test, compressed air for the tightness test

Applied standards

Pressure note. Water 40 MPa applies to the small end of the range. DN350 - DN600 are tested at the pressure their class requires, normally up to 16 MPa. The clamping force and the frame are sized for the largest valve and the highest class you will actually test.
SYJ-600SQ data sheethttps://www.zbcxhb.net/en/price.html

YSYJ-300 - Valve Pressure Test Bench

Vertical, top cylinder, moving worktable, upper and lower inlet
Changxun Machinery
Nanjing, China
ren@zbcxhb.net

DN50 - DN400 / water 40 MPa / air 0.8 MPa

Semi-automatic
Valve size rangeDN50 - DN400
Test pressureWater 0 - 40 MPa; air test 0.8 MPa
Flange diameter580 mm
ClampingTop cylinder o180, maximum clamping force 80 t, stroke 350 mm, extension rod available
StructureVertical, twin column, single beam
WorktableMovable, travel 400 mm - the valve is loaded outside the frame
Water pathsInlet at top and bottom; upper and lower chamber pressurised separately, no second clamping
SequenceLow pressure pump fills, high pressure pump raises to the set value and stops, hold time counts down, alarm at the end of the hold

Applied standards

Pressure note. 40 MPa applies to the small end of the range. The pressure applied on DN300 - DN400 is set by the valve class, and the clamping force is calculated together with it.
YSYJ-300 data sheethttps://www.zbcxhb.net/en/price.html