CHANGXUN | Valve Test Equipment

Home / Valve Test Benches / How to test a butterfly valve

How to test a butterfly valve — shell and seat, and why the liner decides both

A butterfly valve is the cheapest valve to buy and one of the easiest to test wrongly. The seat is not a machined face but a liner that the disc edge presses into, and a wafer body has no flange of its own, so every tonne of clamping force on the bench passes straight through that liner. This page is the sequence for wafer, lug and double-flanged butterfly valves: which plate to use, where the disc has to sit, how to tell a seat leak from a leak at the plate face, and which readings should not be taken at all.

Butterfly valvesShell 1.5 × ratingSeat 1.1 × ratingBoth directions

Get a quotation   Send the DN range, the liner material and the class you test to.

Quick answer

Shell test1.5 × rating, disc clear of the seat (usually fully open)
Seat test1.1 × rating, disc fully closed, each side in turn
PlateBore not smaller than the valve bore; outside diameter matched to the flange face
ClampingEnough to seal the faces, no more — on a wafer body the force goes through the liner
MediumWater by default; air only at low pressure as a bubble check
DiscClosed on its own stop; the operator stays fitted and clear of the bench
After the testDisc part open to drain both sides, liner edge and disc edge dried before packing

What is actually under pressure

“Test the butterfly valve” is two operations with different objects under pressure, and on a large bore they are usually run on different machines. The shell test proves the body and the shaft seals. The seat test proves the liner and the disc edge. A bench reading taken with the disc half open proves neither, which is why the position of the disc belongs on the test record next to the pressure.

TestWhat is under pressureDisc positionWhat you read
ShellBody ring, shaft bores, stem seals, plate-to-liner facesClear of the seat, usually fully openCasting seepage, stem seal leak, water crossing at the plate face
Seat, side AUpstream half of the bore, one face of the linerFully closed, on its stopLeakage past the disc edge into the open (downstream) side
Seat, side BThe other face of the same linerFully closed, on its stopLeakage back through the same disc edge, now in the other direction
Stem sealShaft bore and packing / O-ringsEitherRecorded as its own line — not mixed into the seat number

One liner does the work of two seats here, so the two directions are not independent tests of two parts: they load the same elastomer from opposite sides. That is why a butterfly valve is normally quoted as bidirectional and still has to be proved in both directions — the liner can hold on one side and weep on the other if the disc is off centre or the liner is not seated squarely in its groove.

Trap 1 — a plate that does not match the flange face

This is the most common false leak on a butterfly bench, and it is not the valve's fault. A wafer valve seals on two narrow annular faces. If the blind plate in front of it has a smaller outside diameter than the flange face, or a bore smaller than the valve bore, or a face that is not flat, water crosses between the plate and the liner and appears on the downstream side. It reads exactly like a seat leak.

Three checks before the valve goes in: the plate outside diameter covers the full gasket face; the plate bore is at least the valve bore, so the leak path is not narrowed or blocked; and the plate face is flat and clean. A scored or warped plate gives a repeatable, believable, wrong number.

Trap 2 — clamping a wafer body until the liner gives

A gate valve body is stiff: clamp it hard and the body takes the load. A wafer butterfly valve has no flange of its own, so the same clamp force is reacted by the liner, and the liner is a compression seal, not a crush seal. Past a certain point it deforms, the disc no longer swings freely, the bore closes up slightly, and the seat test fails on a valve that would have passed at the right force.

The symptoms are easy to recognise once you know them: rising operating torque on the gearbox, a disc that rubs at part travel, and leakage that changes every time the valve is re-clamped. On a lug body the clamping is set by bolt torque through the lugs, which is measurable and repeatable; on a wafer body the bench ram sets it, so the bench needs a clamp pressure gauge or a regulator rather than a “tighten until it stops” habit.

Trap 3 — a disc that is not on its stop

On a soft-seated butterfly valve the seal is made in the last part of the quarter turn, where the disc edge is pressed into the liner. Two or three degrees short of the stop is enough to produce a steady weep that looks like a failed seat. The operator has to be worked to the stop and left there, and the position marked on the record, because a valve that is closed “by feel” is a different test every time.

The opposite mistake is using the operator as a support or letting it rest on the bench table. The lever or handwheel is a control, not a stand, and a bent lever can hold the disc off the stop without anyone noticing.

Trap 4 — judging every liner by the same rule

The liner material decides the medium, the temperature and, to a large extent, what the number means:

Liner / seatWater testWhat to watch
EPDMYes — the default mediumSwells in mineral oil; keep oil-based media away from the bench side of the valve
NBRYesOil resistant, but not against every solvent; check the liner grade before a non-water medium is used
PTFE / RTFEYesCold flow under compression — over-clamping deforms a PTFE seat more quietly than an elastomer one
Metal seat (multi-offset)YesMetal-to-metal contact is judged by the leakage rate the order names, not by bubble-tight expectation

A metal-seated valve that shows a slow weep at 1.1 × rating is not automatically scrap. What matters is the class written on the order and whether the disc is fully on its stop with clean sealing faces. The bench produces the observation; the standard and the inspector produce the verdict — the rate classes themselves are set out on the leakage rate classes page.

Trap 5 — the stem seal, counted as a seat leak

The shaft passes through the body on both sides of a butterfly valve, so there are two stem seals, and one of them is usually on the pressurised side during a seat test. A drip from a stem seal is a leak, but it is a different failure from a seat leak and belongs on its own line of the record. Mixing the two produces a repair instruction for the wrong part: the liner gets replaced when the O-ring was the problem.

On the shell test with the disc open, the stem seals are part of the pressure boundary and a weep there does count against the body test. That is the one test where the two are legitimately judged together.

Eight steps on the bench

  1. Identify the body type and the face-to-face. Wafer, lug or double-flanged, and the flange standard. A butterfly body is short face-to-face, so a bench with fixed plate travel needs a spacer rather than a longer ram stroke.
  2. Select the plates. Outside diameter covering the gasket face, bore not smaller than the valve bore, flat face. For a lug body use the bolt pattern and set the clamp by bolt torque.
  3. Mount centred, and swing the disc through its full quarter turn by hand before any pressure is applied. It must clear the plate bore at every position.
  4. Close the disc on its stop and mark the operator position. The operator stays fitted, clear of the bench, and carries none of the valve's weight.
  5. Fill slowly with the valve upright so the highest point of the bore is the vent. Vent until water appears, then close. On a large bore the pocket above a closed disc is worth litres of compressed air.
  6. Shell test at 1.5 × rating with the disc clear of the seat, held for the time the standard names. Watch the stem seals, the body casting and the plate faces, and keep them apart in the notes.
  7. Seat test at 1.1 × rating with the disc on its stop, one direction, then the other. Read the open side; a leak at the plate face is the fixture, not the valve.
  8. Drain both sides, leave the disc part open, dry the liner edge and the disc edge, and record the disc position with the pressure. Water left between a closed disc edge and the liner rusts a cast iron disc and marks the liner.

What the bench must have for butterfly work

ItemWhy it matters on a butterfly valve
Plates matched to the flange faceThe valve has no flange of its own; the plate face is half of the seal
Controlled clamp forceThe liner is compressed, not crushed — repeatability depends on setting the force, not feeling it
Adjustable clear span plus spacersShort face-to-face bodies and lug patterns do not fit a gate valve fixture
Low-pressure, high-flow fillA large bore at PN10 needs litres per minute, not 40 MPa — the opposite of a small-bore gate valve bench
Two gauges across the rangeA 1.1 × PN10 seat test is read on a low-range gauge; a 40 MPa dial cannot resolve it
Drain on both sidesEach seat direction leaves water on the opposite side of the disc
Support for large bodiesA DN800 valve should not hang its weight on the liner while it is being clamped

Which of our machines come up for butterfly work

The range is built around the bore first, and butterfly valves pull the selection towards the large-bore, lower-pressure end — the numbers below are the published envelopes of each model, not a recommendation for a specific valve:

ModelLayoutDN rangeTest pressureClampingWhy it is on this list
ZSYJ-300AVertical, single stationDN50–DN3001.6–40 MPa80 tSmall and mid-size butterfly valves mixed with gate and ball work
SYJ-600SQVertical, water + airDN50–DN60040 MPa water / 4 MPa air90 tShell and seat plus a low-pressure air bubble check on the same frame
SYJ2-300-600Two stationsDN50–300 and DN350–600PN6–PN100One clamp per stationSmall valves and large valves in the same shift without re-rigging
WBD-600Horizontal, ram + 3 jawsDN50–DN6000–16 MPa150 tLarge butterfly valves that have to lie flat on the table
SYJ-600MVertical clampDN350–DN6000–10 MPa126 tLarge bodies in a workshop where crane height is limited

Selection by size is worked through on the DN selection page, and the pressure numbers that go with each class are on the test pressure chart. Fixtures — plate sets, spacers, sealing discs and jaw inserts — are quoted with the machine and listed by model on the spare parts page.

Where a butterfly valve differs from the gate valve on the next bench

If the same workshop tests both, the differences are worth putting on one page of the work instruction: the gate valve seats on two machined faces and can take a hard clamp; the butterfly valve seats on a liner and cannot. The gate valve needs the wedge lifted clear for the shell test; the butterfly valve needs the disc swung clear. And the gate valve body holds air in the bonnet, while the butterfly valve holds it above the disc in a bore that is short and wide.

The gate sequence is written out in how to test a gate valve, the ball valve sequence — including the cavity question — in how to test a ball valve, and the fixture side of the problem in clamping methods. The general order of operations that keeps any reading valid is in the 8-step procedure.

Boundaries worth writing down

The bench does not declare the valve compliant. It produces a pressure record and a leakage observation. Whether that satisfies API 598, ISO 5208, EN 12266-1 or GB/T 13927 is a judgement made by your quality function or the inspector named on the order.

Operating torque is a different test. Break and running torque of an actuated butterfly valve are measured with a torque cell; a standard bench does not produce that number, and fitting one is a quotation item.

Fire-safe, anti-static and fugitive-emission tests are not hydrostatic tests. They are run to their own standards and cannot be inferred from a water test that passed.

Liner temperature is a limit, not a preference. A hot-water test above the liner's rated temperature is a different test on a different valve; the bench being able to hold the pressure does not make the liner able to take the temperature.

The envelope is mechanical. A 16 MPa bench does not become 25 MPa through a larger pump or a different gauge, and a 150 t clamp does not become a licence to close a liner.

Questions we get asked about butterfly valves

Which side do I pressurise for the seat test?

One side, then the other. A soft-seated butterfly valve is normally bidirectional, but the two directions load the same liner from opposite faces, so a single-direction test proves half the valve. Where the order names a preferred sealing direction, test that direction last so the reading you report is the one that matters.

Water appears at the edge of my blind plate. Is the valve leaking?

Probably not. Water crossing between the plate face and the liner face is a fixture leak; a seat leak appears at the open bore, past the closed disc. Check the plate outside diameter, its flatness, the centring, and that the plate bore is not smaller than the valve bore before you condemn the liner.

Can a wafer butterfly valve be clamped in a bench the way a gate valve is?

Yes, with two conditions: the plates must match the flange face, and the clamp force must be controlled rather than applied until it stops. The wafer body has no flange of its own, so the clamping load is carried by the liner. Over-clamp it and the disc binds, the seat distorts, and a good valve fails the seat test.

Should the lever or gearbox be removed for the test?

No. Leave it fitted so the valve is tested as it ships, keep the operator clear of the bench so it cannot take the valve's weight or act as a stop, and work it fully to the closed position before pressurising. A disc a couple of degrees off its stop weeps in a way that looks like a failed seat.

A metal-seated butterfly valve weeps at 1.1 × rating. Is it scrap?

Not necessarily. Metal-to-metal seats are judged by the leakage rate the order names, which is not the same as bubble-tight, and a weep can also come from a disc that is not fully on its stop or a sealing face with debris on it. Read the class on the order before deciding, and record what you saw rather than a pass or fail.

Can I test with oil instead of water?

Only if the liner is compatible. EPDM — the most common water-works liner — swells in mineral oil; NBR is oil resistant but not against every solvent; PTFE is broad but creeps under compression. Water is the default medium, and whatever is used has to be drained and the liner dried before the valve is packed.

Tell us the butterfly DN range, the liner material and the classes on your orders

Send the size band, the body type (wafer, lug or double-flanged) and the standard you test to. You get a model recommendation, a datasheet, the fixture drawing and a price within 12 working hours.