Valve test bench services: used machines, retrofit, data export, remote support, spare parts and maintenance
Six service lines around one machine. A worn bench is rebuilt and sold to a named grade; a sound bench with manual controls is retrofitted to clamp, log and report automatically; a bench that works but produces no paperwork is given per-valve test data export as CSV and PDF; a bench that stops is reached over an outbound tunnel for PLC diagnostics instead of waiting for a flight; a sound bench is kept running from a spare-parts list matched to the machine; and a bench that is working but has never been calibrated since it was installed goes back inside its record on a scheduled visit. Each page states the scope, the acceptance checks and what is handed over.
Quick answer
| Bench worn out, or buying second-hand | Rebuild, sold to grade C / B / A |
|---|---|
| Frame sound, controls still manual | Retrofit: clamping, recipes, logging, reports |
| Machine fine, records missing | Data export per valve, CSV and PDF |
| Bench stopped, fault hard to describe | Remote PLC session, outbound tunnel |
| Need discs, flanges or jaw sets | Spares, quoted by machine model |
| Running, but no calibration record | Scheduled maintenance and calibration visit |
| What no service changes | The pressure envelope: class and bore |
| How a service is accepted | Measured checks, signed against a record |
The six service lines, side by side
One machine, six different problems. The table shows who each service is for and what changes at handover; the detail pages carry the scope lists, the before-and-after tables and the acceptance checks.
| Service | Who it is for | What is delivered | What it cannot do |
|---|---|---|---|
| Used and refurbished benches | Workshops and contractors buying second-hand, or trading an old bench in | Rebuild to grade C, B or A, a load test record, gauge certificates, PLC backup, spare seal set | Change the envelope: a 16 MPa frame is not turned into a 40 MPa bench, and plates do not widen the bore |
| Retrofit to automatic | Plants with a sound bench whose clamping, recipes or reports are still manual | Five retrofit modules: automatic clamping, recipe management, dual-gauge logging, report generation, safety interlocks | Raise the pressure class or add bore; those are set by the pump, the seals and the frame |
| Remote PLC diagnostics | Plants whose bench is far from the supplier, or whose fault cannot be described well enough over the phone | Industrial gateway, outbound tunnel, HMI mirror, I/O and alarm history, programme backup before any change, session log exported to you | Repair anything mechanical, verify a relief valve, calibrate a channel or judge a valve; and it needs a network point the plant will allow out |
| Spare parts | Workshops that know which part wore out and need the right size for the machine | Part list matched against the nameplate, fit notes per part, a wear record sheet, the stock versus made-to-order split | Move the pressure envelope, calibrate an instrument, or quote a part before the model is confirmed |
| Test data export | Manufacturers whose customers ask for per-valve records and who currently write them by hand | Field-level logging, CSV and PDF per valve, USB stick, plant folder or ERP drop folder, file naming agreed at commissioning | Judge pass or fail and issue certificates; the record shows what was measured, the standard and the operator still decide |
| Maintenance and calibration | Plants running a bench, ours or another make, whose per-valve records have to survive a customer or ISO audit | Both gauge ranges as-found and as-left, seal and jaw wear list, oil and filter, water and air circuit, interlock test device by device, a signed visit report | Judge a valve, move the envelope, replace an accredited laboratory certificate, or rebuild a worn machine |
Spares — sealing discs, blind flanges and clamping jaw sets — are matched by machine model: the spare parts page lists every wearing part with the symptom that says it is due. If you need a set now, send the model and the DN range and the part list comes back from the workshop.
Which one fits your situation
Start from the machine, not from the wish list. If the hydraulic circuit weeps, the seals are flat and the paint is gone, the question is the rebuild — or whether the machine is worth rebuilding at all, which the same page answers with the envelope rule. If the frame and the clamping cylinder are sound but the operator still pumps the clamp by hand and reads two gauges with a camera, the question is the retrofit. If the machine does everything you need and the only gap is the paper — a customer audit, an ISO clause, a job file per valve — the question is the data export, which is usually the cheapest of the three because nothing mechanical is touched. If the machine is sound and the problem is that nobody can reach it when it stops, the question is remote PLC diagnostics — the one service on this list that changes nothing at the bench except the gateway in the cabinet. And when nothing is wrong except a worn part, the question is the spare parts list — the shortest decision on this page, and the one that keeps the other lines from being needed. When nothing is broken at all but the bench has never been calibrated since it was installed, the question is maintenance and calibration — the line that decides whether the numbers the other five produce can be defended.
The six are not mutually exclusive. A rebuilt bench can be delivered with its control module already fitted, and an export layer can be added to a machine that was retrofitted last year. The model pages show which modules are factory options on each new bench, so ordering the module new is often the neater route when the machine is being bought anyway.
What every service has in common
Two boundaries hold across all six services, and stating them up front avoids a wasted enquiry on both sides.
- The envelope does not move. Pressure class and bore are set by the pump, the relief setting, the seal material, the plate thickness and the frame. None of the six lines changes them. If your valves sit outside the machine's envelope, the honest answer is a different frame — the DN selection guide is how that decision is made, and the pressure chart shows what each class is held at.
- The record does not replace the standard. A data export records what the gauges read and when; it does not judge the valve. Shell and seat testing follow the standard the valve is sold to — GB/T 13927-2022, API 598 and the class limits behind them — and acceptance of any service is signed against measured checks, not against a promise that a gauge will never move.
Each detail page ends with the same structure: the delivery list, the schedule written as a two-stage process, and the acceptance checks the handover is signed against. That is deliberate, so a service scope from us reads the same way a new-machine offer does.
Buying or selling a bench
- Grades C / B / A
- Six acceptance checks
- Part exchange and consignment
Manual bench, sound frame
- Five retrofit modules
- Per-model module order
- PLC upgrade, cross-brand inputs
Fault a flight away
- Outbound VPN tunnel
- HMI, I/O, alarms, trend
- Session log stays with you
Running, never calibrated
- As-found and as-left
- Both gauge ranges
- Interlock test, device by device
Questions about the services
Do these services apply to benches from other makers?
The control side usually does. The retrofit modules and the export layer work on the PLC, the gauges and the record, and a cross-brand PLC upgrade starts from five inputs: the valve list, the current controls, cabinet photos, the record format your customers ask for, and the safety functions that must stay. A mechanical rebuild of another maker's bench depends on whether drawings and wearing-parts documentation exist, and is answered after inspection.
Can a used bench be bought and retrofitted in one order?
Yes — that combination is the grade A refurbishment: full rebuild plus a control and data module, delivered producing records. Running the acceptance once, covering both the rebuild and the controls, is the practical reason to order them together.
What should we send to start an enquiry?
The machine model or a nameplate photograph, the DN range and pressure class you test, and one sentence on the problem: worn, manual, or missing records. A scope proposal comes back within 48 hours. For a mechanical rebuild the exact scope is written after the machine has been inspected and opened, not before.