Home / Fitting and pipe test benches
Fitting and pipe hydrostatic test benches — tees, crosses, elbows and reducers, DN30 to DN700
Yes, an elbow can be tested. A fitting bench presses two blind plates onto the two ends of the fitting with hydraulic rams, so the plates have to move in height and tilt in angle to meet faces that are neither parallel nor level. That is the whole difference from a valve bench: on a valve the two flange faces are parallel and one clamp holds both, on a tee or a 45° elbow they are not, and the fixture has to follow the geometry. Three frames cover the work — DN30–DN220 to 20 MPa, DN350–DN700 to 3 MPa, and a multi-purpose frame to DN450 at 6.5 MPa.
Quick answer
| What it holds | Tees, crosses, elbows, reducers and other irregular fittings, 0–45° included angle, plus valves on the multi-purpose frame |
|---|---|
| Bore range | DN30–DN220 · DN350–DN700 · to DN450 on the multi-purpose frame |
| Test pressure | 0–20 MPa · 0–3 MPa · 0–6.5 MPa, by frame |
| Clamping | Hydraulic — three rams of 38 t, 150 t, or 78 t depending on the frame |
| What it does not do | It holds pressure and shows it. The pass/fail judgement is made by your quality function or the inspector on the order |
Why a valve bench cannot do this job
A valve bench is built around one assumption: the two faces you clamp are parallel and square to the ram. A gate valve, a butterfly valve, a ball valve — the body sits between two plates and the ram closes along one axis. A tee has three openings at right angles. A 45° elbow has two that meet at an angle, and the centre lines of the two faces sit at different heights. Put that on a valve bench and the plate meets an edge instead of a face.
What changes is not the pump or the pressure gauge. It is the fixture, and there are three adjustments that make a fitting bench different:
- Blind plates that tilt. The side plates adjust through about 45° so the plate face can be brought square to the cut end of an elbow or a lateral rather than to the vertical.
- Plates that move in height. The two ends of a reducer or a tee outlet are not at the same level, so the plate has to be raised or lowered to meet the face instead of clamping on a corner.
- A table that moves. Loading a 1.2 m fitting by crane onto a fixed table is a two-man job with a load hanging over the frame. A moving table brings the open side out from under the frame, the fitting is set on it, and it is rolled back in.
Everything downstream of the fixture — the low-pressure fill pump, the high-pressure pump, the gauge set, the hold timer, the record — is the same equipment as on a valve bench. The hydrostatic test procedure page sets out the eight steps that a body test runs through, and they apply to a fitting unchanged.
The three frames, side by side
These are the fitting frames in the current range. The numbers below are the frame specifications, not a quotation: the fixture set for the actual fitting geometry is planned against the drawing, and that planning is what turns a frame into a machine.
| Frame | Bore and angle | Test pressure | Clamping | Work envelope |
|---|---|---|---|---|
| GJ-SJ-220 irregular fitting bench | DN30–DN220, 0–45° | 0–20 MPa | Three rams, max 3 × 38 t; plates tilt 45°, height adjustable 45 mm | Frame 2110 × 860 × 2000 mm; opening between blind plates to 500 mm; weight about 1 t |
| GJS350-700 large fitting bench | DN350–DN700, 0–45° | 0–3 MPa | 150 t on the top and side rams, ram bore 250 mm, hydraulic system to 31.5 MPa | Fitting 1.2 m × 1.2 m; flange outside diameter 505–806 mm; weight 8 t |
| SJSJ-12 multi-purpose, valves and fittings | To DN450, 0–45° | 0–6.5 MPa | 78 t on the top and side rams, ram bore 180 mm, hydraulic system to 31.5 MPa | Fitting 760 mm high × 790 mm wide; flange diameter to 635 mm; moving table |
All three run on a 380 V supply — 4 kW hydraulic power unit on each frame, plus 1.5 kW on the water pump of the GJ-SJ-220. Voltages and frequencies for other destinations are settled at the quotation, since the pump motor and the control circuit follow the destination.
What sets the pressure ceiling when the bore grows
The plates are pushed apart by the water inside the fitting, and that force is the test pressure multiplied by the area the pressure acts on. Area rises with the square of the bore, so the same test pressure on a bigger fitting needs far more clamping force — which is why the small frame reaches 20 MPa and the large one stops at 3 MPa.
| Frame | Pressure it is rated for | Clamping that holds it |
|---|---|---|
| GJ-SJ-220, to DN220 | Up to 20 MPa | 3 × 38 t |
| SJSJ-12, to DN450 | Up to 6.5 MPa | 78 t |
| GJS350-700, to DN700 | Up to 3 MPa | 150 t |
This is not a limitation that a bigger pump removes. Moving a DN600 fitting from 3 MPa to 10 MPa multiplies the separating force by more than three, and the frame, the rams and the plate thickness all have to be built for it. When the order needs a pressure above the frame's rating, the honest answer is a frame specified for it — the same rule that applies to a valve bench at PN400, set out on the choosing-by-standard page.
The relationship also explains something buyers ask about on small fittings: a DN50 fitting at 20 MPa puts a small load on the plates, so the limitation on the small frame is the bore range and the geometry, not the pressure. Shops that test both small high-pressure fittings and large low-pressure ones usually end up with two frames rather than one, and the size-first selection table is the same logic applied to valves.
Where the test pressure number comes from
A valve test has two pressures because a valve has two jobs: the body has to hold, and the seat has to close. A fitting has only the first. There is no seat, so there is no seat test, and the pressure on the order is a single body test held for a stated time.
That number is usually written as a multiple of the fitting's design pressure or of the line class it is made for, and it is fixed by the purchase order, the project specification or the end user's procedure — not by the bench. The pressure chart lists the 1.5× body figure for PN10 to PN400 as it applies to valves, which is a useful cross-check when a fitting is ordered to the same line class, but the figure that governs is the one on your order.
What to send so the frame can be sized in one pass
A description is not enough for a fitting bench, because the geometry is the machine. Six lines plus a drawing get a model, a fixture set and a price band back:
- A sketch or drawing of each fitting family: tee, cross, elbow, reducer, lateral
- Bore range, smallest and largest, and the wall thickness at the ends
- Outside diameter of each flange or the end preparation, if the ends are bevelled for welding
- Included angle between the two ends, and the centre-to-face lengths
- Test pressure and the hold time the order names
- Destination, power supply and whether the shop loads by crane or by hand
What comes back is a frame, the fixture set for those families, and a test recipe — and, where the geometry does not fit any of the three frames, that answer comes back plainly rather than as a stretched quotation. How a quotation is built line by line is on the price and lead time page; the same twelve lines apply here, with the fixture set in place of the valve clamping jaws.
Boundaries worth writing down
The bench does not declare a fitting compliant. It holds pressure, shows it and records it. Whether the result satisfies the order is a judgement made by your quality function or the inspector named on the order.
The rating is mechanical. A frame rated 3 MPa does not become a 10 MPa frame with a bigger pump, a different gauge or a software setting.
Fixtures are per geometry. A plate set built for a 45° elbow does not automatically take a tee of the same bore; the second family is quoted as an addition, not assumed.
No third-party witness is implied. Where the order requires an inspector to witness the test, that is arranged separately and in advance.
Frequently asked questions
Can one bench test both fittings and valves?
The SJSJ-12 frame does both: valves and irregular fittings to DN450, at 0–6.5 MPa, with 78 t of clamping. The two GJ frames are fitting machines. Where a shop tests valves on one bench and fittings on another, the fitting bench is chosen from the fitting geometry rather than from the valve range — the valve-type page deals with the valve side of that split.
Why does the largest fitting frame stop at 3 MPa?
The force pushing the blind plates apart is the test pressure multiplied by the area of the bore, so it rises with the square of the diameter: going from DN220 to DN700 multiplies that area by about ten at the same pressure. That is why the DN350–DN700 frame is rated 0–3 MPa with 150 t of clamping, while the DN30–DN220 frame reaches 20 MPa with three rams of 38 t.
What test pressure applies to a fitting?
The one the order or the fitting's design pressure names. A fitting has no seat, so the valve shell-and-seat pair does not apply: it is a single body test, held for the time the order specifies. Where an order cites a valve standard, only its body test has a counterpart on a fitting.
What has to be sent to size a fitting bench?
A sketch or drawing of the fitting with the bore, the wall thickness, the outside diameter of each flange, the included angle between the two ends and the centre-to-face lengths; the test pressure; and the destination with its power supply. Angle and height adjustment are what the frame is built around, so a drawing settles the model faster than a description.
Bore, angle, flange outside diameter and the test pressure on the order. We come back with the frame, the fixture set for those families, and say plainly where the envelope stops.